FO-HB9-2022-02 

Focus SBR 

An upper heat shield located directly under the firebox must be removed before the blower can be inserted. 

It is held in place with four c-

clips. Remove the four clips and 

then remove the upper heat shield (see below). 

A flat screwdriver may help with removal of the c-clips. Once removed, insert the blower through the bottom 

louver opening and push it to be back of the fireplace. Center the mounting plate between the two brackets 

and face the air outlet upwards. 

Make sure to re-install the upper heat shield

 

 

 

Pearl 3600, Focus 3600  

Insert the blower into the bottom louver and move it to the back of the firebox. It must pass around the right 

side of the outside air box which is centered in the bottom of the fireplace. Do not remove the outside air 

box. Center the mounting plate between the two brackets and face the air outlet upwards. The thermal 

switch should be placed on the inside of the one for the fireplace legs, 1/8” from the firebox. See below. 

 

 

 

 

Delta Fusion 

The floor shield is made of two parts. Both parts are screwed together and factory installed to cover the 

entire floor below the firebox. Before installing the internal blower, the floor shield must be modified. Remove 

the screw and overlap the front section with the back section. Put the modified floor shield back into the 

bottom of the fireplace against the back. If you ever remove the blower make sure to extend the shield 

again. 

 

Remove the vibration rubber dampers from the 

mounting plate and reinstall them on the blower openings 

(right).  Install the blower inside the lower louver opening with the blower outlet facing the rear of the 

fireplace. Center the blower in the middle of the fireplace, with the blower outlet facing the back of the unit. 

 

 

Outside air box 

Internal blower 

Thermal 

Switch 

Содержание FO-HB9

Страница 1: ... for the blower to operate OPTION 1 THREE PRONG PLUG INSTALLATION The three prong plug setup is best for new installations where the internal blower is the only option that will require electricity 1 An electrical junction box with a three prong plug outlet should be installed in the bottom of the fireplace by a certified electrician in an accessible location 2 Ensure no wires contact the firebox ...

Страница 2: ... page for the correct orientation and assembly Installation of the Internal Blower 1 Remove the bottom louver of the fireplace If your fireplace has a magnetic bracket located on the right side of the bottom louver opening remove the magnetic bracket If your fireplace is equipped with an ash pan remove the ash pan plug ash pan and the ash pan support by unscrewing the screw located at the back of ...

Страница 3: ...nting plate between the two brackets and face the air outlet upwards The thermal switch should be placed on the inside of the one for the fireplace legs 1 8 from the firebox See below Delta Fusion The floor shield is made of two parts Both parts are screwed together and factory installed to cover the entire floor below the firebox Before installing the internal blower the floor shield must be modi...

Страница 4: ...pan support the ash pan and the ash pan plug if necessary Installation of the thermal switch Install the thermal switch which is a heat activated switch that will turn your blower on and off as the fireplace heats or cools Placement is important Place the thermal switch to the inner right leg or outside air box below the firebox Space the switch 1 8 from the fireplace bottom the magnet will hold t...

Страница 5: ...FO HB9 2022 02 Wiring for terminal block installation Connect the wiring as shown below N Ground 120Vfrom breaker L ...

Отзывы: