Connect the AC/DC power supply to the SpotDAP unit first, then to the
correct voltage power source. The SpotDAP unit will automatically turn
on. The Status LED wil show green. See page 5 for more detail in
connecting the AC/DC power supply to the SpotDAP unit.
Adjusting the SpotDAP unit volume:
The SpotDAP unit requires audio from a line level external audio
source, with volume control such as a CD player, DVD player or
MP3 player.
Stop the external audio source.
Connect the RCA cables.
Turn the external audio sound on.
Adjust the external audio source’s volume until you reach
the desired level from the SpotDAP unit.
When the SpotDAP unit detects that incoming signals are signifi-
cantly beyond the input rating of the unit, it automatically lowers
the signal until the limiter can reduce the input level to within
operating limits.
Adjusting the SpotDAP EQ settings:
The SpotDAP unit comes programed with 3 selectable EQ
settings. See page 22 for frequency response plots showing the
effect of each EQ setting. The factory default is EQ setting #1.
!
NOTE:
It is always best to begin with a low volume level at the source.
OPERATING INSTRUCTIONS
#1 Normal
#2 Bass Cut
#3 Bass Boost
GENERAL SPECIFICATIONS
SYSTEM MODEL Nos. SpotDAP450/SpotDAP460
ULTRASONIC & DSP PROCESSING
Carrier Frequency:
Variable 40 - 50 kHz
Modulation Method: Proprietary Dynamic Double Sideband
ULTRASONIC EMITTER
Type:
Proprietary Monolithic Film Transducer
AUDIO
Analog Input Section:
Input Impedance:
10k Ohms
A/D
Converter:
16
bit
Input Connector:
2 RCA style connectors
Input Channels:
RCA1, RCA2
System Configuration:
Monaural (Two input channels
summed together on the RCA
connectors)
Max Input Level Before Clipping:
160 mVrms x1 channel
or
80
mVrms
x
2
channels
System:
Bandpass Filtering:
400Hz to 16KHz
Max Audio SPL Output:
SpotDAP450 85db @ 1KHz/1 meter
SpotDAP460 91db @ 1KHz/1 meter
POWER AMPLIFICATION (ALL UNITS)
Amplifier
Type:
Proprietary
Modulation
Amplifier
(MODAMP®)
7
16
Operating the SpotDAP Unit
OPERATING INSTRUCTIONS