TROUBLESHOOTING AND FREQUENTLY ASKED QUESTIONS (FAQ)
Technical Engineering Questions
How much AC power is needed?
See the General Specifications section on page 17 for power requirements
Does feedback occur using a live microphone with a SpotDAP system?
SpotDAP systems allow you to direct the produced audio away from any live
Additionally,
SpotDAP signal processing further reduces the potential for feedback.
What governmental or safety agency approvals are required for SpotDAP?
SpotDAP systems manufactured for RSF by American Technology Corporation
(ATC) will meet and/or exceed the following government and safety
requirements and regulations:
CSA
For Professional Use Only
CE
OSHA (USA) OSHA Technical Manual, Section III, Chapter 5, Section V,
Table III: 5-4 “TLV’s For Ultrasound”
FDA (USA) American Technology Corporation (ATC) has submitted the
applicable reports to the FDA pursuant to Title 21, CFR, subchapter J as it
pertains to ultrasonic devices for other than medical device applications.
The abbreviated report is pursuant to Section 1002.12 of the regulations
According to this report, the FDA has assigned the following Accession
numbers to SpotDAP (HSS ) products: 0181485 and 0191486.
®
FCC (USA) This device complies with the FCC Rules for a Class A Digital
Apparatus.
NOTE:
Set-up Environment
Temperature:
Do not expose the SpotDAP unit to direct sunlight for extended periods as
the emitter in the SpotDAP unit can be damaged by extremes of heat or cold.
Observe and maintain the temperature limits as described in the General
Specifications section, page 18.
Humidity:
Avoid direct exposure to water. If the SpotDAP unit is moved and the temperature
change causes condensation on the unit, allow the emitter surface to dry,
unaided, before applying power. Observe and maintain the humidity limits as
described in the General Specifications section, page 18.
Vibration:
Any electronic device can be affected by excessive vibration. Although the
SpotDAP unit is not particularly sensitive to vibration, use sound judgment as you
would when installing any electronic device.
Dust and Dirt:
Avoid installing the SpotDAP unit where the emitter will be subjected to excessive
dust and dirt. See the Maintenance section (page 8) for details on managing
environmental dust. Contact SpotDAP Service at +352 49.74.20.40
or [email protected] for information on operating the SpotDAP unit in an
excessive dust or dirt environment.
Ventilation:
Keep the SpotDAP unit’s vents unblocked. A minimum clearance of 3 inches (7.5
cm) should be maintained to allow unrestricted ventilation with convected
INSTALLATION NOTES
!
CAUTIONS ON HANDLING:
Use caution when handling the device. Be
sure that no foreign objects come into contact with the emitter
surface (the silver/copper foil surface behind the front grill).
airflow.
9