13
1-3 Electrical Specifications
Accuracy is given as ±(% of r counts
of least significant digit) at 23°C ± 5°C,with
relative humidity Less than 80% R.H.
ACV and ACA specifications are ac coupled,
true R.M.S. The crest factor may be up to 3.0
as 4000 counts.
For non-sinusoidal waveforms, Additional
Accuracy by Crest Factor (C.F.) :
Add 3.0% for C.F. 1.0 ~ 2.0.
Add 5.0% for C.F. 2.0 ~ 2.5.
Add 7.0% for C.F. 2.5 ~ 3.0.
Position Error of Clamp: ±1.5% of LCD reading.
DC Current
Range
Resolution
Accuracy
60.00A
(1)
0.01A
±(1.5% +10D)
(2)
300.0A
0.1A
±(1.5% + 5D)
All specifications are valid from 5% to 100%
of each range.
(1) There is less than 0.3A variation as
measuring in different directions.
(2) Add 10D to accuracy in Auto AC & DC
Sense Mode.