background image

Trouble shooting of antenna system DELTA 200 S 
 

1.  

No function of any instruments connected to the AV 205 incl. VHF 

 
1.1.  

Check the cable installation according to the installation plan. 

 
1.2. 

Check if the green indicator lamp of the AV 205 lights. 

 
1.2.1.   Indicator lamp lights 

Check  the  cable  between  AV  205  and  the  antenna  DELTA  200  S  for  break.  Checking  the 
resistance of the antenna incl. antenna cable with an ohmmeter will indicate 25 - 100 Ohm. 

 
1.2.2.   Indicator lamp is off 
 
1.2.2.1. Check the power supply of the  AV 205 and  the fuse inside  the AV 205 (0.5  A medium blow; 

5×20 mm). 

 
1.2.2.2. Disconnect the antenna cable at the AV 205. If the indicator lamp lights now, there is a short  
 

circuit at the antenna cable or at the antenna DELTA 200 S. 

 
1.2.2.3. If the indicator lamp still is off, there is a fault at the AV 205 - pull out the plug-in modules of  

the AV 205 (make a note of their position!). If the indicator lamp lights now, one of the modules  
is defective, otherwise the AV 205 is faulty. 

 
2.  

No function of a single instrument connected to the AV 205 

 
2.1.  

If  the  instrument  is  connected  to  output  1  or  output  2,  check  if  a  suitable  plug-in  module  is  

 

inserted properly into the AV 205. 

 
2.2.  

If  the  instrument  is  connected  to  one  of  the  fixed  wideband  outputs  (3  or  4)  or  to  a  plug-in  

 

module BB, check if the trimmer potentiometer associated with the output is turned on. 

 
2.3.  

Check the cable between the AV 205 and the instrument for short circuit or break. 

 
2.4. 

If the instrument has several antenna inputs, assure that the correct antenna input is selected  
 at the instrument. 

 
The  antenna,  the  distribution  box  and  the  plug-in  modules  may  be  repaired  by  authorized 
specialists only! 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Отзывы: