FIREBRICK INSTALLATION
The appliance comes with the fi rebrick packaged inside.
Brick size: 9” x 4-1/2” x 1-1/4” (Royall pin number fi rebrick standard split).
Model 6130
Model 6300
Model 6490
Models
6150 & 6200
MODEL 6130 (6) Full Bricks & (2) Cut Brick
Starting in the BACK lay 3 full brick then 1 cut brick.
Repeat for 2nd side.
MODEL 6150 & 6200 (12) Full & (2) Cut Bricks
Starting in the BACK of the unit, place ½ brick on end,
then add 4 full brick on end. Last lay 2 full bricks side
down. Repeat for 2nd side.
MODEL 6300 (18) Full Bricks & 2 Cut Bricks
Starting in the BACK stand 1 cut brick then 7 full brick
side by side. Then lay 2 bricks stacked side to side in the
front. Repeat for 2nd side.
MODEL 6490 (36) Full Bricks
Starting at the BACK stand 12 full brick side by side. Then
lay 6 full brick down on top of 12 lower ones. Repeat for
2nd side.