6.6 Roof exhaust with traditional
fireplace
The chimney for the evacuation of flue gases
must be made by qualified personnel in compli-
ance with standards UNI 10683- EN 1856-1-2- EN
1857-EN 1443- EN 13384-1-3- EN 12391-1 both in
terms of the dimensions and the materials used
in its construction.
The evacuation of flue gases via a traditional
chimney (
Fig. 17
) can be done as long as you are
sure of the state of maintenance of the chimney.
In the case of an old chimney, it is advisable to
renew it using ducting.
The flue gas exhaust must be on the roof.
1
3
2
Fig. 17
1)
Wind proof cowl
2)
Seal
3)
Inspect
If the chimney has a larger section, it
must be “intubated” with a suitably in-
sulated steel pipe (with diameter suita-
ble for the route
(Fig. 18)
.
Make sure that the connection to the brickwork
chimney is properly sealed.
In case of pipes that pass through
wooden roofs or walls, it is recommend-
ed to use special certified ducting kits
commonly available on the market.
1
3
2
Fig. 18
1)
Non-combustible material
2)
Steel piping
3)
Closing panel
Содержание RONDINE AIR
Страница 33: ......
Страница 46: ...46 004778620 23 11 2020 4 2 Dimensions 553 527 934 Ø 80 263 252 235 5 Ø 2 5 Fig 5 ...
Страница 64: ...64 004778620 23 11 2020 ...
Страница 95: ...ITALIANO ENGLISH DEUTSCH FRANÇAIS ESPAÑOL 004778620 23 11 2020 95 ...
Страница 108: ...108 004778620 23 11 2020 4 2 Abmessungen 553 527 934 Ø 80 263 252 235 5 Ø 2 5 Abb 5 ...
Страница 126: ......
Страница 157: ......
Страница 158: ......
Страница 159: ......