Royal Sovereign RDH-470P Скачать руководство пользователя страница 6

6

This unit is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be used in accordance with the National Electrical Code and 

applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange 

the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any 

circumstances, be cut or removed. Never use the cord, the plug or the unit when they show any sign of damage. Do not use your unit with an extension cord unless 

it has been checked and tested by a qualified electrical supplier. Improper connection of the grounding plug can result in risk of fire, electric shock and/or injury to 

persons associated with the unit. Check with a qualified service representative if in doubt that the unit is properly grounded.

IMPORTANT - GROUNDING METHOD

Before plugging the unit into an electrical outlet, check that:

• The electrical power supply corresponds to the value indicated on the rating plate on the back of the unit.

• The power socket and electrical circuit are adequate for the unit.

• The electrical power matches the plug. If this is not the case, have the plug replaced.

• The electrical power is adequately grounded. Failure to follow these important safety instructions absolves the manufacturer of all liability.

ELECTRICAL CONNECTIONS

DESCRIPTION

1. Control panel

2. Air outlet

3. Bucket

4. Window

5. Caster Wheels

6. Handle

7. Air intake grille

8. Drain Hole

9. Power cord

Содержание RDH-470P

Страница 1: ...del RDH 470P DEHUMIDIFIER WITH BUILT IN AUTO PUMP Owner s Manual Royal Sovereign International Inc Please read and retain these instructions To register your product please go to www royalsovereign co...

Страница 2: ...nstructions for optimal use and proper care and maintenance for your product Safety Information 3 Description 6 Control Panel and Product Operation 8 Maintenance of Unit 12 StoringTheUnit 12 Tips On S...

Страница 3: ...g the power cord 11 Do not use outdoors Intended for indoor use only 12 Place the product in an area where the temperature will not fall below 41 5 The coils can become covered with frost if the room...

Страница 4: ...The grounding instructions are not completely understood 2 You are unsure that the unit is properly grounded 3 You have any questions about the grounding or electrical instructions 1 Avoid the use of...

Страница 5: ...sed in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equip...

Страница 6: ...electrical supplier Improper connection of the grounding plug can result in risk of fire electric shock and or injury to persons associated with the unit Check with a qualified service representative...

Страница 7: ...from the bucket 3 Reinstall the cover and handle Carefully place the bucket back into the unit BEFORE USE Castors and other accessories 7 1 Tilt the unit no more than 45 and push the caster wheels int...

Страница 8: ...isplayed as shown button On Off Button 8 Decrease Increase button Press to select the desired humidity level or to set the time The humidity adjustable range is 35 RH 80 RH The screen will display the...

Страница 9: ...ll Alarm When the bucket is full the compressor will shut off and the fan will stop for a few minutes A beep will sound to indicate that the bucket needs to be emptied The symbol will flash Important...

Страница 10: ...16 Ft 4 9m in height If you want the water to flow directly to a drain connect the condensation discharge tube supplied to the connection pipe located on the lower front part of the unit Select the de...

Страница 11: ...around and above space away from the wall for efficient working 4 Place the dehumidifier in an area where the temperature will not fall below 5 41 5 Use the dehumidifier in cooking laundry bathing an...

Страница 12: ...nit from the electrical outlet empty the bucket remove the cap Run off all water left into a basin When all the water has been drained put the cap back in place Clean the filter and dry thoroughly bef...

Страница 13: ...ction The fuse is blown circuit breaker is tripped Check the house fuse circuit breaker box and replace fuse or reset breaker Bucket is not in the proper position The bucket must be in place and secur...

Страница 14: ...removal rate This model is designed to operate at temperatures above 5 41 Check that all doors windows and other openings are securely closed The capacity of the unit can not meet the area of the roo...

Страница 15: ...CODE If the following error code appears contact Royal Sovereign customer service Error code EH E1 E2 E3 Description Humidity sensor failure Temperaturesensorerror Temperature sensor error Gas leakag...

Страница 16: ...persons or service centers mishandling improper installation modification or unreasonable use including incorrect voltage acts of God or failure to provide reasonable and necessary maintenance This w...

Страница 17: ...TEUR POMPE AUTOMATIQUE INT GR E Guide d utilisation Royal Sovereign International Inc Veuillez lire et conserver ce guide d utilisation pour consultation ult rieure Pour enregistrer votre produit visi...

Страница 18: ...r une utilisation optimale ainsi que l entretien et la maintenance de votre produit Consignes de s curit 19 Description 22 Panneau de contr le et fonctionnement du produit 24 Entretien de la tranche 2...

Страница 19: ...le mettre hors fonction et d brancher le cordon d alimentation 11 Ne pas utiliser l ext rieur Destin un usage int rieur uniquement 12 Placez le produit dans un endroit o la temp rature ne descendra pa...

Страница 20: ...ne sont pas enti rement comprises 2 Vous n tes pas s r que l appareil est correctement mis la terre 3 Vous avez des questions concernant la mise la terre ou les instructions lectriques 1 vitez l util...

Страница 21: ...aux instructions peut causer des interf rences nuisibles la radio communications Cependant il n y a aucune garantie que des interf rences ne se produiront pas dans une installation particuli re Si cet...

Страница 22: ...de la fiche de mise la terre peut entra ner un risque d incendie d lectrocution et ou de blessure pour les personnes suivantes les personnes associ es l unit En cas de doute sur la mise la terre de l...

Страница 23: ...Remettez le couvercle et la poign e en place Remettre soigneusement le seau dans l appareil AVANT L UTILISATION Roulettes et autres accessoires 23 1 Inclinez l appareil de 45 maximum et poussez les r...

Страница 24: ...at s affiche comme indiqu Bouton Bouton de mise en hors fonction 24 Bouton d augmentation diminution Appuyez sur pour s lectionner le taux d humidit d sir ou pour r gler l heure La plage d humidit r g...

Страница 25: ...e Pour annuler appuyez sur le bouton Le symbole dispara t Alarme de bac plein Lorsque le bac est plein le compresseur s arr te et le ventilateur s arr te pendant quelques minutes Un bip retentit pour...

Страница 26: ...e 4 9 m 16 pi Si vous voulez que l eau s coule directement dans un drain raccordez la condensation Tuyau de refoulement fourni la conduite de raccordement situ e sur la partie inf rieure avant de l ap...

Страница 27: ...efficace 4 Placez le d shumidificateur dans un endroit o la temp rature ne descendra pas en dessous de 5 41 5 Utilisez le d shumidificateur dans les zones de cuisson de lessive de bain et de lavage de...

Страница 28: ...la prise lectrique vider le seau retirer le bouchon Faire couler toute l eau qui reste dans un bassin Lorsque toute l eau a t vidang e remettez le bouchon en place Nettoyez le filtre et s chez le soig...

Страница 29: ...t d clench V rifier le bo tier du fusible disjoncteur de la maison et remplacer le fusible ou le disjoncteur de r enclenchement Le bac n est pas dans la bonne position Le bac doit tre en place et soli...

Страница 30: ...s ambiantes plus basses r duiront le taux d limination de l humidit Ce mod le est con u pour fonctionner des temp ratures sup rieures 5 41 V rifiez que toutes les portes fen tres et autres ouvertures...

Страница 31: ...d erreur suivant s affiche contactez le service client le de Royal Sovereign Code d erreur EH E1 E2 E3 Description D faillance du capteur d humidit Erreurducapteurdetemp rature Erreur du capteur de te...

Страница 32: ...s une mauvaise manipulation une mauvaise installation une modification ou une utilisation d raisonnable y compris une tension incorrecte un cas de force majeure ou un d faut d entretien raisonnable e...

Отзывы: