Using Your Fire Table
1.
Make sure the Control Knob (1
3
) is in the “OFF” position.
2.
Open the Door and slowly open the Valve (22) on the Propane Gas
Tank by turning the Cont
rol
Knob (1
3
) counterclockwise.
3.
Close the Door on the Main Frame (0
6
) of the Fire Table.
4.
Push and hold in the Electronic Ignit
ion
to create sparks within the
electrode continue to hold.
5.
Push in the Control Knob (1
3
) and turn to the “LOW” position.
Keep holding down the Control Knob (1
3
) to allow gas to flow for 15
seconds.
6.
If ignition doesn’t occur within a few seconds release the Control Knob
(13)
and rotate to the “OFF” position.
Wait for 5 minutes for gas to clear and then repeat the above lighting
instructions.
7.
Once the Fire Table / Column is lit, the flame intensity may be
controlled by turning the Control Knob (1
3
) between the “LOW” and
“HIGH” positions
Operation
NOTE: Whenever gas connections are loosened or removed, you must
perform a complete leak test. Complete installation.
8
.
Observe flame height when lit:
1
) Flame color should be yellow / blue.
2
) Flame height burns at 2 - 10 inches high.
2 inches to 10 inches