Swii’Flo
-- USER’S GUIDE -- EUG
ROXELL --022 -- 2313
29
PROBLEM
CAUSE
CORRECTIVE ACTION
h. Debeaked birds.
- Install start cups.
i. Not enough water consumption by
day-olds.
- Increase pressure.
- Increase lighting.
j. Too many birds per nipple.
- Adjust the stocking rate.
k. Use of another system during rear-
ing of layers/breeders.
- Temporarily reduce the water pressure
and use start cups.
l. Drip cup too large (starting period)
or too small (end of the flock).
- Consult the recommendations types of
bird/nipples/drip cups.
4. Contamination of
the drip cups.
a. Not enough birds per drip cup.
- Temporarily use less lines. Check the in-
dividual nipples.
b. Nipples are silted up (calcium/iron). - Agitate the nipples to let water through
them to rinse.
5. Obstruction to the
movement of birds.
a. Lines are suspended too low.
- Adjust the height.
6. The synthetic ma-
terial of the drip
cup is affected.
a. Use of non-authorized products.
- Consult the list of allowed products be-
fore using any of them.
7. Leaking connec-
tors.
a. Incorrect installation.
Too high pressure.
- Use the correct tools and follow the in-
structions.
- Check position of the flush button on the
pressure regulator.
- Check if valve of the end unit is open dur-
ing flushing.
8. Connectors get
loose.
a. Too much water pressure on the
line.
- First open end valve for flushing in case
of manual flushing.
Maximum water pressure = 3 BAR.
b. Incorrect procedure when rinsing.
- See instructions part 1.
c. Broken clamp ring 19802941.
- Replace clamp ring and follow the in-
structions.
9. Deformed tubes.
a. Heat source is too close.
- Remove the heat source, so that the line
is no longer exposed to a temperature of
more than 50
_
C.
10.Perching animals in
case of electric
poultry perch sys-
tem.
a. No cable for poultry perch guard in-
stalled.
- Install cables for poultry perch guard or
perch protection system when needed.
b. Cable for poultry perch guard is not
electrified.
- Make a correct connection to the poultry
perch guard.(turn on).
Check on short circuits.
c. Cable for poultry perch guard not
stretched enough.
- Control by expert.
d. Wrong connection between the
poultry perch guard and the line.
- Wrong connection between the poultry
perch guard and the line.
e. There is no earthing.
- Provide correct earthing.
f. The animals tend to perch on the
line.
- For breeders/layers : winch up the lines
every evening and/or encourage the birds
from the lines before switching off the
lights.
Содержание Swii'Flo
Страница 1: ...02205284 02205284 022 0821 User Guide EN ENGLISH Original User Guide ...
Страница 14: ...Swii Flo USER S GUIDE EUG ROXELL 022 2313 7 FIGURE 6 4 3 5 6 7 Clean with water REGULAR CLEANING ...
Страница 17: ...ROXELL 022 0513 Swii Flo USER S GUIDE EUG 10 FIGURE 9 1 1 1 1 3 4 3 4 OPERATION WITH MEDICATOR 3 4 3 4 3 4 ...
Страница 19: ...ROXELL 022 0513 Swii Flo USER S GUIDE EUG 12 FIGURE 11 1 1 1 1 3 4 3 4 1 DIVIDED HOUSES NORMAL OPERATION ...
Страница 20: ...Swii Flo USER S GUIDE EUG ROXELL 022 2313 13 FIGURE 12 1 1 1 1 3 4 3 4 1 DIVIDED HOUSES OPTION MEDICATION ...
Страница 43: ......