ROXELL --022 -- 2313
Swii’Flo
--
USER'S GUIDE
-- EUG
28
TROUBLE SHOOTING GUIDE
Switch off the main switch first.
Use personal protective equipment.
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
If you must replace leaking nippels, remove them carefully.
Screw the nipples vertically into the pipe, so that you do not deform the screw thread.
Do not screw the nipple too deep.
Caution
IMPORTANT
PROBLEM
CAUSE
CORRECTIVE ACTION
1. Leaking nipples.
a. Dirt in the system when starting up
.
- Rinse the lines before using them.
b. Bad water quality.
- Have the water tested by a renowned
specialist and take action if needed.
c. Vaccines/medicines.
- Rinse the lines before and after adminis-
tering additives.
d. Water is polluted.
- Regularly clean the filter cartridge.
Use clear water.
e. Wear of nipples.
- Regularly adjust the height of the lines.
f. Use of certain detergents/disinfect-
ants/medecines.
- Consult the list of allowed products and
check specifications of suppliers before
using any of them.
g. Nipple is not suitable for the type of
bird.
- Consult the recommendations types of
bird/nipple.
2. Water wastage.
h. Water supply at the wrong spot.
- See instructions for the maximum length
per water supply point.
i. Scope is too high.
- Install the water supply at the correct po-
sition.
Refer to instructions on the slope regula-
tor.
j. Incorrect height of the line.
- Adjust the height.
k. Wrong combination of nipple/type of
bird.
- Consult the recommendations types of
bird/nipple.
l. Drip cup is not suitable for the type
of bird.
- Consult the recommendations types of
bird/nipple.
m. Water pressure set too high.
- Adjust water pressure as recommended,
as a function of the age of the animal.
3. Water consumption
too low.
a. Incorrect level of the line :
- Uneven floor.
- height of the line.
- Level the litter on the floor.
- Adjust the height.
- Regularly adjust the height of the line.
b. Water is too hot.
- Rinse every hour with fresh, cool water.
You can use the RFC (Roxell Flushing
Controller) to do this automatically.
c. Nipple is not suitable for the type of
bird.
- Consult the recommendations types of
bird-nipple.
d. Water pressure is too low.
- Adjust the water pressure.
e. Nipples are silted up (vaccination/
medicines).
- Refer to the supplier's instructions for the
specific means to be used to release the
nipples. Follow the specifications and in-
structions for use of these means.
f. A large number of nipples are
blocked by a too high content of
calcium/iron.
g. Pollution of individual nipples.
- Move the nipple bars a few times to and
fro until the dirt comes off or replace the
complete nipple.
Содержание Swii'Flo
Страница 1: ...02205284 02205284 022 0821 User Guide EN ENGLISH Original User Guide ...
Страница 14: ...Swii Flo USER S GUIDE EUG ROXELL 022 2313 7 FIGURE 6 4 3 5 6 7 Clean with water REGULAR CLEANING ...
Страница 17: ...ROXELL 022 0513 Swii Flo USER S GUIDE EUG 10 FIGURE 9 1 1 1 1 3 4 3 4 OPERATION WITH MEDICATOR 3 4 3 4 3 4 ...
Страница 19: ...ROXELL 022 0513 Swii Flo USER S GUIDE EUG 12 FIGURE 11 1 1 1 1 3 4 3 4 1 DIVIDED HOUSES NORMAL OPERATION ...
Страница 20: ...Swii Flo USER S GUIDE EUG ROXELL 022 2313 13 FIGURE 12 1 1 1 1 3 4 3 4 1 DIVIDED HOUSES OPTION MEDICATION ...
Страница 43: ......