Working with Components
Rovema VPK Operators Manual
3/2000 VPK REV(B) PANELVIEW 600
8-5
Replacing Heater Cartridges and Temp Probes
Vertical Sealing Device
At some point, the heating cartridges and the temperature probe inside
of the seal band unit must be replaced. Use the following procedure
to replace these items. Before starting this procedure, make sure that
the bagmaker is locked-out and that the seal band unit has cooled.
To replace the heating cartridges and the temperature probe:
1.
Remove the seal band drive unit from the heating bar assembly by
removing the two hex head bolts that secure it to the assembly.
Note:
The seal band drive unit is heavy. Use two people to remove
the unit from the machine.
2.
Remove the terminal housing from the heating bar assembly to
expose the ceramic connectors.
Figure 8.5
Shows how to remove the seal band drive unit from the heating bar assem-
bly.
Heating Bar
Assembly
Hex Head
Bolt
Seal Band
Drive Unit
Terminal
Housing