background image

Moving Workcenter with Cabinets

Déplacement des postes de travail avec cabinets

This section only applies to workstations 

that can not be assembled in their intended 
final location.

Each cabinet must be anchored underneath a work 
surface. See page 4.

Cabinets must be anchored together. See gang 
anchoring on page 5.

Move workcenters by placing the points of contact (forks 
of pallet jacks) under cabinets as illustrated bellow.

For workcenters with several cabinets, make sure you 
have no more than one RA30 cabinet (not supported by 
a pallet jack) placed between two cabinets supported by 
a pallet jack when moving.

Raise it about 1/4" off the ground and make sure weight 
is distributed evenly on forks.

Section s'appliquant uniquement aux postes 

de travail ne pouvant pas être assemblés 
directement à leur emplacement prévu.

Chaque cabinet doit assemblé sous la surface de travail. 
Voir page 4.

Les cabinets doivent être ancrés ensemble. 
Voir ancrage mitoyenne à la page 5.

Déplacer le poste de travail en placant les points de 
contact (fourche des transpalettes) sous les cabinets tel 
qu'illustré ci-dessous.

Pour les postes de travail avec plusieurs cabinets, il faut 
s'assurer de ne pas avoir plus d'un cabinet RA30 (non 
supporté par un transpalette) placé entre deux cabinets 
soutenus par un transpalette lors d'un déplacement.

Soulever d'environ 1/4'' au dessus du sol et s'assurer 
que le poids est distribué également sur les fourches.

Narrow pallet jack

Transpallette étroit

20.5''

2x

1x 

or/

ou 

2x

24'' 

cabinet width

largeur des cabinets

30'' min 

cabinet width

largeur des cabinets

rousseaumetal.com

1-800-463-4271

Wide pallet jack

Transpallette large

27''

LA30

Cabinet

LA30

Cabinet

RA30

Cabinet

RA30

Cabinet

LA30

Cabinet

LA30

Cabinet

RA30

Cabinet

RA30

Cabinet

LA30

Cabinet

RA30

Cabinet

LA30

Cabinet

RA30

Cabinet

Standard OR wide pallet jack

Transpallette standard ou large

RA30
LA30

+

USE WIDE PALLET JACK / 

UTILISER TRANSPALETTE LARGE

Page 6/7

Содержание Modular Cabinet R Line

Страница 1: ...t to reach the drawers above 60 in a secure manner La hauteur du dernier tiroir ne doit pas exc der 60 moins que vous ne poss diez l quipement ad quat pour acc der aux tiroirs au dessus de 60 de fa on...

Страница 2: ...t must be anchored as indicated Floor Anchoring Ancrage au sol 3 7 8 3 3 8 1 3 8 X 3 1 4 deep prof for concrete pour b ton Here Ici Here Ici 2 4 9 16 Le cabinet doit tre ancr aux endroits pr vus l arr...

Страница 3: ...seaumetal com 1 800 463 4271 Page 3 7 Stacking Cabinet Cabinet de superposition 4x 4x 4X Top view Vue de dessus Recessed Base Base en retrait Standard Base Base standard Base cover Cache base 2 3 4 1...

Страница 4: ...deep cabinet compatible with 30 and 36 deep steel top WS10 12 Cabinet de 21 de profond compatible avec dessus WS10 12 de 24 Cabinet de 21 de profond NON compatible avec dessus WS10 12 de 30 et 36 Cabi...

Страница 5: ...r de serrer les boulons C C 4 2 Front view Vue de face Front view Vue de face C 5 Do not tighten completly Ne pas serrer compl tement Boulons 5 16 18 5 16 18 Bolts 3L120202 4x 8x C 3 5 16 18 Nylon loc...

Страница 6: ...ace de travail Voir page 4 Les cabinets doivent tre ancr s ensemble Voir ancrage mitoyenne la page 5 D placer le poste de travail en placant les points de contact fourche des transpalettes sous les ca...

Страница 7: ...de ses composantes ex tiroirs et ancr la surface de travail par 4 vis voir page 4 Standard pallet jack Transpallette standard 20 5 2x 2x 24 cabinet width largeur des cabinets 30 min cabinet width lar...

Отзывы: