WarMer DraWer
10
P/N 1011046 08/09
trOUbleshOOtInG
warnInG
to avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical
equipment should be performed by qualified service personnel. the unit should be unplugged when
servicing.
problem
possible cause)
corrective action
unit will not heat up.
Power cord is not plugged in.
Plug the Power cord into the appropriate out-
let.
circuit breaker is tripped.
reset the circuit breaker. contact your elec-
trician if the breaker trips again.
Hi-Limit thermostat is tripped or
inoperable.
Hi-Limit thermostat will reset automatically
once the unit cools down. if after cooling the
unit still does not heat up, contact your main-
tenance person or authorized service agency
for service.
Loose, broken, or burnt wiring in
Heating circuit.
contact your maintenance person or
authorized service agency for service.
faulty Heating element.
contact your maintenance person or
authorized service agency for service.
faulty thermostat control.
refer to
Replacing the Thermostat Control
in
the Maintenance section of this manual.
contact your maintenance person or
authorized service agency for service.
Product becomes hard and
dry.
thermostat control is too high.
readjust the thermostat control.
Product is not being kept in its
original packaging.
refer to the Operating instructions section of
this Manual.
Product is kept beyond the normal
holding times.
refer to the Operating instructions section of
this manual.
unit is getting too hot.
thermostat control is set too high.
readjust the thermostat control.
faulty thermostat control.
refer to
Replacing the Thermostat Control
in
the Maintenance section of this manual.
contact your maintenance person or
authorized service agency for service.