9
8.
Setting up synchronous control
When you use two or more transmitters within the same area, noise reduction in the interfering areas
might be obtained by synchronizing the reference clocks of each transmitter.
Choose one as the master transmitter and the rest as slaves. For slave equipment, place the jumper
plug between pins 1 and 2 of the JP1 (inside the main body).
How to set up the slave equipment
1.
Disconnect the AC adaptor. Remove the 4 screws specified below with a screwdriver and pull up
the cover.
Pull up the cover vertically
L IN
R IN
FM TRANSM ITTER
YS ‑10 10 S
LOCK
COMP
INT
MON
ST
POWER
Remove the screws in the
same place on the back side
Remove the screws in the
same place on the back side
Remove the jumper
from pins 3-4 to pins
1-2.