background image

 

5

  Stereophonic transmission indicator 

   

The red LED will be on during stereophonic transmission. 

 Stereophonic/monaural changeover 

Changeover switch for stereophonic and monaural transmission. For monaural transmission, 

connect either the input L or R, or reduce the input level to half (-6dB) if you connect to both 

input L and input R. 

 Power 

   

  The green LED lights up and the transmitter starts to operate when the power is turned on. 

 

 

 

  4.

Rear Panel 

 

① 

DC input 

A terminal for supplying power from an external source. Connect the AC adaptor contained in 

the accessory kit. If you use other power supplies, verify the input voltage range (DC11

DC18V) and the polarity. Please choose a power source with the least noise. Use a DC jack of 

5.5mm (-) external diameter and 2.1mm (+) internal diameter for connection. 

② 

DC output 

Output voltage will be lower by 1V (approx.) than the input voltage supplied by DC input.  

The maximum output current is 300mA. Built-in devices are a reversal protection diode, a 

current limiting fuse, and a surge protection (33V) device.   

Содержание YS-1010S

Страница 1: ...Ver 1 03 2004 07 zip 158 0082 6 40 10 todoroki setagaya ku tokyo japan Phone 81 3 3703 1211 Fax 81 3 3703 1215 ROUGH AND READY INC URL http www randr co jp ...

Страница 2: ...apparatus to rain or moisture when installed outdoors 5 Do not give abnormal voltage over the permissible range when you input signals 6 In case you open the covers of the transmitter disconnect the power adaptor first and be careful not to touch and damage the parts inside the transmitter during the manipulation Key features Small sized and high spec in design and by virtue of its low power consu...

Страница 3: ...or the visually handicapped 2 Composition The composition of this unit is shown below Please check to ensure whether you have all required components No Name Quantity Specifications 1 YS 1010S Mainbody 1 2 Connector 1 MOLEX 5051 04 for synchronous control 3 Terminals 5 MOLEX 5159 for synchronous control 4 AC adaptor 1 DC12V output 5 Antenna holder 1 With magnets BNC connector type 6 Antenna 1 Rod ...

Страница 4: ...within the range of 0 5Vp p 6Vp p approximately Preset at input level of 2Vp p and 75KHz deviations at the time of shipment Composite input For input from external sources using stereocodic signals and closed caption signals Input 2Vp p for stereocodic signal and the transmitter outputs 75KHz deviations Input 0 2Vp p for closed caption signal and the transmitter outputs 7 5KHz deviations Internal ...

Страница 5: ...r is turned on 4 Rear Panel DC input A terminal for supplying power from an external source Connect the AC adaptor contained in the accessory kit If you use other power supplies verify the input voltage range DC11 DC18V and the polarity Please choose a power source with the least noise Use a DC jack of 5 5mm external diameter and 2 1mm internal diameter for connection DC output Output voltage will...

Страница 6: ...setting switch Set up a transmission frequency 3 digits by a step of 0 1MHz and within the range of 76 0 90 0MHz RF LEVEL adjustment Adjust the transmitter s output level It increases up to 30dB as you turn the adjustor clockwise RF OUT connector The output connector BNC receptacle of the transmitter External equipment such as an antenna a booster and a leaky coaxial cable can be connected Use a c...

Страница 7: ...er starts to operate Use a DC plug specified below or a PCAB 02 cable option when supplying power to external equipments from this transmitter DC plug Attention Check the polarity before connecting the cable If you supply excess current over 300mA from this transmitter to the external equipment the power will be shutdown automatically In the case of this happening disconnect the power supply cable...

Страница 8: ... B to Analog input Right red two channel mixer output will be transmitted as monaural broadcast Transmit the composite input For transmission of the composite input yellow the transmitter s audio characteristics are determined by the signal characteristics of the connected composite input since VCO will be directly modulated to FM bypass those of input filter pre emphasis circuit stereo multiplexe...

Страница 9: ...For slave equipment place the jumper plug between pins 1 and 2 of the JP1 inside the main body How to set up the slave equipment 1 Disconnect the AC adaptor Remove the 4 screws specified below with a screwdriver and pull up the cover Pull up the cover vertically L IN R IN FM TRANSMITTER YS 1010S LOCK COMP INT MON ST POWER Remove the screws in the same place on the back side Remove the screws in th...

Страница 10: ...10 Equivalent circuit of synchronous control Replace the jumper from3 4 to 1 2 ...

Страница 11: ... the synchronous control N Attention Getting the reduction of clock radiation noise from the connecting cable for synchronous control the shortest cabling of sealed cables or coaxial cables e g 1 5D2V will be most desirable ...

Страница 12: ...o of modulation distortion 0 4 TYP S N ratio 60dB TYP Stereo separation 46dB TYP Stability of pilot signal 19KHz 0 5Hz or less Pilot signal phase difference 5 or less Audio input power level 750mVrms VR center 12dB 8dB variable input impedance 10KΩ or more Composite input 2Vp p input impedance 1KΩ or more Optional functions Synchronized CLK input output PLL Locked indicator Red LED Stereo Indicato...

Страница 13: ...13 10 Outside drawings DC OUT 11 18V DC IN 0 1 1 10 SYN CLK FREQ MHz RF LEVEL RF OUT L IN R IN FM TRANSMITTER YS 1010S LOCK COMP INT MON ST POWER FM TRANSMITTER MADE IN JAPAN S N 03A00100 mm ...

Страница 14: ...mbers The cost of transportation and lodging of our personnel for providing services at your site is not covered by this warranty services Product name Stereo FM Transmitter YS 1010S Purchase date YY MM DD 2004 Product number First Name Family Name Postal code Phone Address E mail Inquiries If you would like to make any inquiry or to give us your opinion about our products please contact the follo...