5. INITIAL SETTING UP
Before applying any power to the master station you may wish to check that the internal settings of the
jumpers match your system requirements. These jumpers will have been factory set to the default positions, or
to user specified positions, prior to dispatch.
In addition to the internal jumpers there may be a need for you to fit external links to achieve satisfactory
operation of your installed unit. These links can be fitted prior to installation.
The main pcb cover carries a label giving details of all the connection jumper settings and also showing how
to install the field cabling. There are no jumper settings or links to be made on the display pcb on the door.
5.1 Jumper and Link Settings
The main circuit board contains a number of Jumpers and Links to set some parameters for the performance of
the unit. These are factory set and the unit will be fully operational. However there are links which you may
need to fit to match your particular application. There are no jumper links on the display board that require
customer adjustment.
The diagram Fig. 6 is a view of the main circuit board with the door open and on the left.
The function of the jumpers and links is listed in the table below, please note that some select the type of
integrated circuit used, and therefore may vary from one unit to another.
(no = not fitted, yes = fitted)
Jumper / Link .
Function
Default
Action
J1
Dual Port Memory size select
no
not applicable
J2
EPROM select
B position
set EPROM size
J3
EPROM select
A position
set EPROM size
J4
RAM select
B position
set RAM size
J5
Port 1 mode
A position
select RS232
J6
Port 1 RTS
A position
select RTS
J7
Port 2 CTS
A position
select CTS
J8
Port 2 mode
A position
select RS232
J9
Port 2 RTS
A position
select RTS
J10
Port 1 CTS
A position
select CTS
J11
Memory Capacitor discharge
no
not discharged
J12
Watchdog reset disable
no
enable reset
J13
Plant power monitor
no
check main power supply
J14
Plant power external supply
yes
use main power supply
J15
Flash memory
A position
enable support
LK1
P+Q jumpers (physical address)
no
not applicable
LK2
Not fitted
Содержание Pakscan IIS
Страница 1: ...Publication S130E Issue 1 0 23 June 1996 Pakscan IIS Master Station Technical Manual...
Страница 4: ...4 Publication S130E Issue 1 0 Pakscan IIS Technical Manual...
Страница 8: ...8 Publication S130E Issue 1 0 Pakscan IIS Technical Manual This page is intentionally left blank...
Страница 12: ...12 Publication S130E Issue 1 0 Pakscan IIS Technical Manual This page is intentionally left blank...
Страница 60: ...60 Publication S130E Issue 1 0 Pakscan IIS Technical Manual This page is intentionally left blank...
Страница 68: ...68 Publication S130E Issue 1 0 Pakscan IIS Technical Manual This page is intentionally left blank...
Страница 72: ...72 Publication S130E Issue 1 0 Pakscan IIS Technical Manual This page is intentionally left blank...
Страница 83: ...Pakscan IIS Technical Manual Issue 1 0 Publication S130E 83 This page is intentionally left blank...