Rotor Gastronom GK900
17
CH-3661 Uetendorf
© Rotor Lips AG
Instruction Manual
English
10. MAINTENANCE
11. TROUBLESHOOTING
PROBLEM
CAUSE
/
SOLUTION
The appliance doesn’t run
- See chapter “Safety features and
Protection“; overload switches
- Make sure the mains cable is plugged into a
wall socket
- Check the fuse in the applicable building
electrical circuit
- Brushes worn (more than 1 000 operating
hours) contact your service center
The motor only runs at highest speed
when the appliance is switched on
- Defective electronics (service center)
The motor is difficult or impossible to
adjust
- Defective potentiometer or electronics
(service center)
The motor stops under load
- The overload switch has been activated
- Brushes worn (service center)
- Defective electronics (service center)
The motor continues to run even after
the lid has been lifted
- Defective safety switch or electronics
(service center) - risk of accident
Cutter head.:
simply rinse and, if necessary, scrub off.
Never place into water or the dishwasher.
Threaded ring:
should be cleaned especially inside, by using a hard brush.
Bowl:
clean by hand using hot water and a commercial cleaning product, they can also
be cleaned in the dishwasher without cutter head.
Polycarbonate:
To avoid damaging, it is essential to ensure that the plastic parts are removed
during washing.
Use in the dishwasher of special rinse aid for plastics (polycarbonate)!
Stainless steel:
Under unfavourable conditions
rust
may appear at stainless steel parts resulting
from external sources, for example
from iron particles of the supplying water
pipeline or of steel wool sponges. Chloride load (by regeneration salts,
disinfectant, etc.) is to be avoided.
- The motor bearings are permanently lubricated and therefore require no maintenance.
- The cutter head bearing is heavily loaded. Replace cutter head when loose or becomes
noisy.