background image

Window and Door Technology

Roto E-Tec Drive 

Control Unit

Test set

Installation and operation instructions 

for the manual control unit

Содержание E-Tec Drive

Страница 1: ...Window and Door Technology Roto E Tec Drive Control Unit Test set Installation and operation instructions for the manual control unit ...

Страница 2: ...tact Copyright May 2019 Roto Frank Fenster und Türtechnologie GmbH Wilhelm Frank Platz 1 70771 Leinfelden Echterdingen Germany Phone 49 711 7598 0 Fax 49 711 7598 253 info roto frank com www roto frank com ...

Страница 3: ...9 Security Stipulated use 10 Safety information 11 Information on the product Parts list technical features 12 Functional principle and operation 13 Installation Installing the driver 14 Installing the software 15 Operation Connecting the Roto E Tec Drive 16 Setting the Roto E Tec Drive 17 Setting the Roto E Tec Drive 18 Operating the Roto E Tec Drive 19 Running a firmware update 20 Reading operat...

Страница 4: ...iation Hardware for windows and balcony doors Guidelines advice on the product and on liability Directive FPKF issued by the Gütegemeinschaft Schlösser und Beschläge e V quality assurance association Restrictor and cleaning stays for Tilt Only sashes and Tilt Only fanlights Instructions and information issued by profile manufacturers e g manufacturers of windows and balcony doors The applicable re...

Страница 5: ...s that connect the window and the drive to each other Planning engineer The planning engineer target group includes construction engineers architects and the authority making the tender Building element dealers or installation companies The building element dealers or installation companies target group includes all companies and individuals that purchase windows and balcony doors from window and ...

Страница 6: ...structions Directive on attachment of supporting fitting components for turn only and tilt turn fittings TBDK Guidelines advice on the product and on liability VHBH Guidelines advice for end users VHBE CE marking for windows BPR Machinery Directive if applicable Declaration of Conformity in accordance with EN 14351 1 with specifica tion of conditions of use if a window with drive is placed on the ...

Страница 7: ... the constructor installed the drive in an existing window becomes manufacturer When installing a complete power operated window the permissibility of the application must be checked Risk assessment to check the planning specifications see chapter Responsibilities of the planning engineer Responsibility of the builder The builder must hand over the following documents to the end user Maintenance a...

Страница 8: ...revent personal injury and property or environmental damage The warning instructions that relate to handling are identified differently according to the severity of the associated danger The signal words and the associated warning symbols used are clarified below DANGER Immediate risk of death or serious injuries f f Observe these warning instructions to avoid personal injuries WARNING Potential r...

Страница 9: ...nstallation specifi cations and non compliance with the application diagrams or application ranges Increased contamination Claims made by third parties against the hardware manufacturer on ac count of damage resulting from misuse or failure to comply with the obliga tion to give instructions on the part of hardware dealers the window bal cony door manufacturer the constructor of the power operated...

Страница 10: ...y assurance association Applicable national laws and directives see page 4 Any use that goes beyond or differs from the stipulated use is considered misuse Application areas Roto hardware product ranges Roto NT except NT Designo I Roto AL540 with flush encased gearbox without mishandling device Roto ALDesigno with flush encased gearbox without mishandling device without tilt distance reduction Ope...

Страница 11: ...can be unlocked as a result of incorrect installation or improper operation which can lead to the window sash falling out if no restrictor and cleaning stay is installed on the Tilt Only sash f f Restrictor and cleaning stays must be installed on Tilt Only sashes if none are present CAUTION Danger of crushing and trapping due to opening and closing forces Movable parts of the drive can cause injur...

Страница 12: ...e following installation instructions apply in connection with this document Roto NT timber IMO_63 NT IMO_127 NT Designo II Roto NT PVC IMO_64 NT IMO_128 NT Designo II Roto AL IMO_21 AL540 KF IMO_73 AL540 TF IMO_159 ALDesigno Roto E Tec Drive IMO_311 WARNING Misuse may pose a risk of death Misuse and incorrect installation of hardware can lead to serious injuries f f Only use hardware combinations...

Страница 13: ...low the instructions on the rear of the Control Unit to perform a function test To be able to use all of the Control Unit functions in full install the software supplied on a PC or laptop and control the Roto E Tec Drive using the com puter connected by the USB cable Also use the USB connection with the computer to change the drive set tings and run software updates System requirements The PC that...

Страница 14: ...drive Save the file in a directory of your choice Unzip the file and install the driver 1 Double click on the driver file to start installing the driver 2 Confirm any security warnings that appear by clicking on Ausführen Run 3 Confirm extraction of the driver 4 Accept the license agreement and confirm the following steps of driver installation by clicking on Weiter Next Once you have successfully...

Страница 15: ...ive with software version 5 0 or more recent set the slide switch on the Control Unit to NEW left Installing the software 1 Launch the installation program by double clicking on it The PC searches for the preselected COM port 2 Click on Verbinden Connect to establish the connection between the PC and Roto E Tec Drive You are able to use all the functions once you have established the con nection b...

Страница 16: ...on Connecting the Roto E Tec Drive 3 Open the Einstellungen Settings tab to view and change the settings for the Roto E Tec Drive INFO Changed settings do not become active until they are trans ferred to the Roto E Tec Drive by clicking on Konfiguration schreiben Write configuration ...

Страница 17: ...ss the OPEN push button three times the window is opened in the tilt posi tion and closed again after ten minutes as standard You can change this ventilation period as required 1 Enter a value between 1 and 60 to set the ventilation period 2 Click on Konfiguration schreiben Write configuration to transfer the changed value to the Roto E Tec Drive Setting the tilt distance 1 Enter a value between 5...

Страница 18: ...ic signals Acoustic signals provide assistance especially when you are setting the Roto E Tec Drive You can activate and deactivate these according to requirements 1 Activate required signals and deactivate unnecessary ones INFO Deactivate the acoustic signals of the Roto E Tec Drive to minimise operating noise e g in bedrooms 2 Click on Konfiguration schreiben Write configuration to transfer the ...

Страница 19: ...or between the movable parts of the Roto E Tec Drive while the drive is moving Click on the corresponding button for operation Button Function Auf Open Window opens Stop Drive process is interrupted Zu Close Window closes Lüften Ventilation Ventilation process starts with the currently set parameters Positions Reset Position reset The position reset can be used to correct malfunctions the final po...

Страница 20: ...the connection to the PC is stable f f Never switch off the Control Unit under any circumstances 1 Contact your specialist retailer and ask them to send you the latest firmware version or a link to download it You will receive an update file and a password which you need for installation 2 Copy the update file bin file format to the PC being used to connect to the Roto E Tec Drive 3 Ensure that th...

Страница 21: ...ta You can use the Control Unit software to simply read the operating data of your Roto E Tec Drive 1 Ensure that the Roto E Tec Drive is connected to the PC 2 Open the Betriebsdaten Operating data tab for a fast overview of your Roto E Tec Drive 3 If necessary share the values with the service engineer for diagnostic purposes ...

Страница 22: ...clicking on OK Error when establishing communication Most COM port and timeout errors occur when a cable has not been connected when the slide switch on the Control Unit is not set to NEW left or when the drivers have not been installed correctly Please refer to the chapter Establishing communication with the Roto E Tec Drive for this purpose 1 Check the cable connections between the PC and Contro...

Страница 23: ... or balcony doors and the hardware including any accessories Hardware is produced in accordance with current environmental protection standards The materials can be recycled separately Follow the basic instructions below for the proper disposal of hardware f f Observe the information and specifications for disposal contained in the other applicable documents f f Separate hardware components from w...

Страница 24: ...ank com www roto frank com From a single source Optimum hardware systems to meet all challenges Roto Tilt Turn The Tilt Turn hardware system for windows and balcony doors Roto Sliding Hardware systems for large sliding windows and doors Roto Door Matching hardware technology everything about doors Roto Equipment Additional technology for windows and doors ...

Отзывы: