ENGLISH
15
The surfaces to be welded must be cleaned immediately before welding. Protect the
surfaces from weather conditions.
3.2.2 Preparing the socket welding device
Mount the socket welding device.
Mounting using the G-clamp
The socket welding device is supplied with a G-clamp that can be used
to attach it firmly to a workbench.
Introduce the top section of the G-clamp into the slot in the bottom
of the unit.
Mount the unit on the edge of the workbench and tighten the screw
of the G-clamp until the unit is firmly held in place
Mounting without the G-clamp
Spread out the legs and rest the socket welding device on a flat
surface, ensuring that it is stable.
Precaution: The unit must not be connected to the mains supply and used for welding
whilst the G-clamp has not been mounted. The legs can be used to position the unit
once it has been removed from the case, to mount the adapters when cold, etc.
Mount the correct adapters for the diameter of the tube to be welded onto the heating plate.
Locate the male and female adapter halves on each side of the
heating plate and bolt them to it using the allen key supplied with
the equipment.
In order to mount the adapters onto the heating plate, make sure that the plate is cold
and that the unit is unplugged.
Connect the unit to the power source (230V/110V).
Check that the red power LED lights when the unit is plugged in.
Select the working temperature with the regulator knob. Turn the regulator knob to the work-
ing position.