ENGLISH
12
5. Addition of further refrigerants
Whenever new refrigerants are available which are not yet included in the ROCOOL 600, they will
be provided for download on www.rothenberger.com free of charge.
Use
to start refrigerant upload. Choose the desired .txt. file and click „Write“ to write the new
refrigerant on the ROCOOL 600.
6. Recording
1.
Repeatedly press SET
(4)
until the display of the ROCOOL 600 shows the sample rate (e.g. Sr30).
The number indicates the time interval in seconds between two samples.
2.
Press Play / Pause
(8)
and REC
(6)
for 5 seconds until the recording parameters time, date and
year appear on the display of the ROCOOL 600.
3.
After 5 seconds the displays changes back to the main screen.
4.
Use the REC
(6)
button to change between record- and main screen.
5.
The display of “Ext Mem“ or “Int Mem“ indicates whether data is stored on the external or
internal
memory
Î
whenever the Red Box is connected the data is stored on the external
memory. Whenever no Red Box is connected the data is stored on the internal memory.
6.
Press Play / Pause
(8)
to stop recording
Î
the hourglass indicates when the storage process is
completed.
7.
Press Del
(7)
for 5 seconds to delete the internal or external memory. The delete process may
take a few minutes.
Î
when the Red Box is connected the external memory gets deleted.
When no Red Box is connected the internal memory gets deleted.
Î
In doing so all records
will be deleted off the respective memory!