20
ENGLISH
Risk of serious injury! The heating plate can reach temperatures of over 300°C / 572°F!
We highly recommend storing the heating plate in the designated carrying frame
immediately after use!
The welding machine is equipped with a Type 400 digital temperature controller.
The digital temperature controller has been ideally configured and set before leaving our factory.
To set temperature simply press the
F
key until “_SP” is indicated in the display. The opera-
tor can now adjust the setpoint temperature between 0-300°C / 32-572°F with the arrow keys.
If no keys are pressed, the display indicates the actual temperature, the controller automatically
sets the new temperature parameter. As long as the actual temperature is lower than the set-
point temperature, the red arrow flashes (low). If the actual value is larger than the setpoint val-
ue, the red arrow flashes (high). If the actual temperature corresponds with the setpoint temper-
ature, the green bar illuminates. Should the actual surface temperature of the heating plate not
correspond with the actual temperature indicated, it is possible to enter an “offset”. To define the
offset, press and hold the
F
key until “InP” appears in the display (approx. 7 sec.); release
F
key, then press the
F
key as many times as required until “oFS” appears. Correct this
value as required. To save the new settings, press and hold
F
key until the actual value re-
appears in the display.
Warning! Do not change any other heating plate parameters!
Factory settings:
Menü „CFG“
„S.tu“
0
„h.Pb“
1.0
„h.lt“
0.68
„h.dt“
0.17
„h.P.H“ 100
„rst“
0
„P.rE“
0
„SoF“
0
„Lb.t“
0
„Lb.P“
25
„FA.P“
0
Menü „InP“
„Ctr“
8
„tYP“
16
„FLt“
0.1
„FLd“
0.5
„dP.S.“ 0
„Lo.S“
0
„HI.S“
300
„oFS“
xx
„HI.A“
0
„Lo.L“
0
„HI.L“
280
Menü „Out“
„AL.n“
0
„r.o.1“
0
„r.o.2“
0
„Ct.1“
20
„Ct.2“
20
„rEL.“
0
Menü „PAS“
„Prot“
32
Note: The autotuning function could cause the details under “CFG” to deviate minutely. Should
hunting occur, the autotuning function can be activated while the heating plate is cold (set
the menue item “S.tu” to “2” (two) in CFG menue, the system automatically resets the pa-
rameter to “0” (zero).
For lifting the milling equipment and the heating element, use lifting device 53410 or 53323, or a
suitable tool.
3.2.2 Measures for preparing welding
Pipes smaller than the maximum welding range (diameter) of the machine, mount the
adapter clamping inserts suited for the pipe diameter with the Allen screws found in the ac-
cessories kit.
ROWELD P200B: Ø63-140mm: consisting of six wide-surface shells and two small-surface
shells. Ø160-180mm: consisting of 8 wide-surface shells.
ROWELD P160-355B: consisting of six wide-surface shells and two small-surface shells.
ROWELD P500-630B Plus: consisting of six wide-surface shells and two small-surface shells
(for diameters up to 450 mm) or 8 wide-surface shells (for diameters >500 mm).
In so doing, please observe that the small-surface shells are mounted to the two lower external
main clamps. These are used in the left basic clamping element below and above only for pipe
to pipe bend connections.
Содержание 055180H
Страница 159: ...NOTES ...