Rotex Heating Systems GmbH
51
10
TECHNICAL SPECIFICATIONS
Unit category
C13; C 33; C43; C53; C63; C83: C93
Initial gas pressure
G20 ; 20 mbar; G25: 25 mbar; G31: 30/ 37 / 50 mbar
Suitable for gas
IT, ES, CZ : II2H3P
FR : II2Esi3P
DE : II2ELL3P
BE : I2E(S)
PL
: II2E3P
Technical data
RKOMBG*AAV1
22
28
33
Domestic water
Nom. load upper value
kW
6.1 – 25.9
8.0 – 32.3
8.3 – 36.3
Nom. load lower value
kW
5.6 – 23.3
7.1 – 29.1
7.6 – 32.7
Nom. output
kW
5.9 – 22.7
7.7 – 28.4
8.2 – 32.1
Domestic water threshold
l/min
2
Domestic water quantity 60°C
l/min
6
7.5
9
Domestic water quantity 40°C (mixed)
l/min
10
12.5
15
Domestic water temperature
°C
60
Effective unit wait time*
sec
<1
Domestic water side pressure difference
kPa
See par. 5.2
CH
Nom. load upper value**
kW
6.1 – 25.9
8.0 – 32.3
8.3 – 36.3
Nom. load lower value**
kW
5.6 – 23.3
7.1 – 29.1
7.6 – 32.7
Nom. output
kW
5.9 – 22.7
7.7 – 28.4
8.2 – 32.1
Max. CH water pressure
bar
3
Max. CH water temperature
°C
90
Other data
Gas consumption (G25)
m
3
/h
0.67 – 2.80
0.85 – 3.50
0.91 – 3.93
Gas consumption (G20)
m
3
/h
0.58 – 2.42
0.74 – 3.02
0.79 – 3.39
Gas consumption (G31)
m3/h
0.22 – 0.92
0.28 – 1.15
0.30 – 1.29
Pressure loss of the unit (CH)
mWk
See par. 7.4
Electrical data
Mains voltage
V
230
Safety class
IP
IP44
Absorbed power: full load
W
80
Absorbed power: part load
W
40
Absorbed power: standby
W
2
Installation measurements and weight
Height
mm
590
650
710
Width
mm
450
Depth
mm
240
Weight
kg
30
33
36
* Time needed from beginning of draining in order to achieve a temperature increase of 40K to the hot water outlet of the device based on the
CW-hot water flow.
** Maximum CH power is set at the factory at 60% of the highest value (see par. 7.3 Setting CH power).
Содержание RKOMBG22AAV1
Страница 1: ...ROTEX Heating Systems GmbH RKOMBG22AAV1 RKOMBG28AAV1 RKOMBG33AAV1 Installation instructions English...
Страница 55: ......
Страница 56: ...885527 4P374379 1A...