background image

4 Maintenance and cleaning

Operation manual

9

R0 R035A4AA
Wall-mounted condensing boiler
3P469438-6D – 2017.07

#

Description

U09

If parameter is 1, comfort mode preheating will depend
on the user record. It will preheat the water according to
the previous day user records.

If parameter is 2, comfort mode preheating will be
independent of the user record, and at the highest
comfort level (3-star comfort according to EN 13302).

If parameter is 24, comfort mode preheating will be
independent of the user record.

Note: 

If you increase the comfort level, the energy

consumption increases.

U10

Room temperature setpoint used by ROTEX
Opentherm room thermostat during night mode. Only
visible in case ROTEX Opentherm room thermostat is
connected.

To use the user settings menu

1

Press  the  "Enter"  button  when  the 

  icon  is  displayed  on  the

menu level 1 screen.

Result: 

You can see the parameter values on menu level 2.

2

Select an index between "00" and "10" with the right dial.

3

Press  the  "Enter"  button  when  the  parameter  that  you  want  to
change is displayed.

Result: 

You  can  see  the  menu  level  3  screen.  Up  and  down

arrows will appear.

4

Change the parameter with the right dial.

5

Press  the  "Enter"  button  to  confirm  or  the  "Cancel"  button  to
cancel. You will return to menu level 2 after pressing "Enter" or
"Back"

a

b

c

a

Menu level 1

b

Menu level 2

c

Menu level 3

3.5.4

Installer settings menu

Only  qualified  persons  are  allowed  to  enter  the  installer  settings
menu.

4

Maintenance and cleaning

WARNING

The  boiler  should  be  maintained  by  authorised  persons
every year.

Annual  maintenance  cycle  is  very  important  for  safe  operation  of
your boiler and to ensure reliable, efficient and long lasting operation
of it.

Contact your service agent for details.

DANGER

Incorrect  maintenance  and  repairs  can  lead  to  injury  and
material damage.

▪ Never attempt to perform maintenance work or repairs

on the unit yourself.

▪ Contact your service agent.

4.1

To clean the outer surface of the
unit

Clean the outer surface of your boiler with a damp cloth and a little
solvent-free soap.

CAUTION

Sprays,  solvents  or  cleaning  agents  containing  chlorine
can damage the exterior, the fittings or the control unit. Do
not use them for cleaning purposes.

5

Energy saving tips

▪ Operating the unit in central heating ECO mode provides the most

economical central heating operation conditions.

▪ Do  not  run  the  boiler  in  domestic  hot  water  comfort  mode.

Domestic hot water comfort mode involves pre- and post-heating,
which is luxury, not necessity.

▪ Close the thermostatic radiator valves when ventilating the rooms.

▪ The  largest  heat  loss  occurs  through  windows  and  outer  doors.

Check  windows  and  doors  for  air-tightness.  Close  any  blinds  at
night.

▪ Do not hide radiators behind large furniture (i.e. couch, desk, etc.).

Minimum  50  cm  of  clearance  must  remain,  otherwise  the  heated
air cannot be circulated and the room will not heat up efficiently.

▪ Do  not  let  your  room  become  too  hot.  Decreasing  the  room

temperature during the day saves energy.

▪ Have  your  combi  boiler's  maintenance  performed  at  least

annually.

▪ Provide your building with sufficient heat insulation.

▪ Thermostatic  valves  should  be  used.  Each  room  should  be

adjusted  according  to  comfort  conditions.  For  reception  rooms,
this  is  20°C,  living  rooms  22°C,  kitchens  18°C  and  bedrooms
18°C.

▪ Prevent radiators from getting covered by curtains.

6

Contact

Contact  a  local  competent  service  agent  if  you  have  any  questions
regarding the maintenance and repair of your system. You can find
the  contact  information  of  our  competent  services  at  www.rotex-
heating.com

7

Error codes

#

Problem

Solution

10-64

Gas valve circuit error Perform reset. If problem repeats,

contact your service agent.

10-65

Gas valve current
error

Perform reset. If problem repeats,
contact your service agent.

11-64

Ignition does not take
place

Make sure valve on the gas line is
opened. Perform reset after third
unsuccessful ignition trial.

11-65

Flame stabilisation
fault

Wait for boiler's ignition trial.

11-66

Flame signal loss in
safety time

Perform reset after third
unsuccessful ignition trial. If problem
repeats, contact your service agent.

11-67

Flame loss during
operation

Temporary error. Wait for boiler to
re-ignite.

Содержание R2CND028A4AA

Страница 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler R2CND028A4AA R2CND035A4AA R2TND028A4AA R2TND035A4AA...

Страница 2: ...pply Filling loop R2CND028A4AA R2CND028 Instantaneous External R2CND035A4AA R2CND035 Instantaneous External Model Type Domestic hot water supply Filling loop R2TND028A4AA R2TND028 Storage tank Externa...

Страница 3: ...Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modifications on Boiler Gas water or power supply Flue system 2 4 Gas con...

Страница 4: ...oiler Status Description Standby When there is no heat demand the status indicator shows this with a kind of breathing pulsation of the blue and white LED Flame At the moment flame ignites for central...

Страница 5: ...ater operation is active Operation mode Description Winter mode Both domestic hot water operation mode and central heating operation mode are enabled The boiler can produce domestic hot water as well...

Страница 6: ...dial Increasing or decreasing the setpoint value reflects to the central heating water temperature and the room temperature respectively The and icons are shown on the screen when central heating oper...

Страница 7: ...ling When an error occurs the normal behaviour of the user interface is interrupted and the status of the status indicator is affected However be aware that not all errors have the same effect on the...

Страница 8: ...dependency 1 1 2 or 24 U10 Room temperature setpoint used by ROTEX Opentherm room thermostat during night C 18 10 30 User settings menu Parameters detailed Description U00 When using outdoor sensor ab...

Страница 9: ...of your boiler with a damp cloth and a little solvent free soap CAUTION Sprays solvents or cleaning agents containing chlorine can damage the exterior the fittings or the control unit Do not use them...

Страница 10: ...eeded If problem repeats contact your service agent E1 66 Calibration conditions fault No reset needed Wait burner to restart If problem repeats contact your service agent E1 67 Missing calibration Pe...

Страница 11: ...Solution UA 66 BCC ID of internal EEPROM is inconsistent Contact your service agent UA 67 BCC is missing Contact your service agent UA 68 BCC is not compatible with PCB BCC ID Contact your service ag...

Страница 12: ...usland Our partners abroad Unsere Partner im Ausland Nos partenaires l tranger Le nostre sedi all estero Neustros representantes en el extranjero Nasi partnerzy za granic Na i partne i v zahrani http...

Отзывы: