RTX-IOM-QTF-R01-0217
Page
7
of
26
4.1 Safety Notes
Keep hands and clothing away from valve ports and actuator pinion at all times.
Ensure air supply has been disconnected from actuator before any disassembly takes
place.
Never remove end caps when actuator is pressurized.
Actuators must be sized accurately for proper operation
Operating actuators over temperature or pressure limits will result in damage to
actuators.
4.2 Technical Specifications
Mounting is in accordance with ISO 5211/DIN 3337/VDI/VDE 3845 (NAMUR).
Dimensions are as per
Rotex Manufacturers & Engineers Private Limited
Technical
Brochure.
4.3 Operating Conditions
Supply pressure, max
(Standard)
Model
psi
bar
kg/cm2
Direct Acting
116
8.0
8.1
Spring return
116
8.0
8.1
Operating temperature, max
(Standard)
Model
Deg F
Deg C
Direct Acting
176
80
Spring return
176
80
Содержание QTF 100