Initial start-up
16
BA ROTEX GSU - 09/2007
Dirt filter in the heating return flow and cold water inlet
If the ROTEX GasSolarUnit is connected to a heating or cold water system, in which piping or radiators made of steel or non-
diffusion-proof floor heating pipes are used, sediment and swarf can enter the boiler or the stainless steel corrugated tube heat
exchanger and cause blockage, local over-heating or corrosion damage. ROTEX therefore recommends the installation of a
contamination filter in the heating return or cold water feed (
15 60 11
for units up to 28 kW,
15 60 12
for units up
to 50 kW).
Surface temperature
– In ambient air-independent mode, at rated power, the design does not allow temperatures > 80°C on any component located
outside the unit cladding panels. Therefore, no minimum distance is required to components made from flammable materials.
– A minimum distance of 50 mm between the flue gas duct and flammable components should be maintained in a partial ambi-
ent air-independent and ambient air-dependent mode.
– Do not use easily flammable and easily combustible substances directly next to the ROTEX GSU.
Installation in garages
The ROTEX GSU is entirely suitable for installation and operation within a garage. Requirements:
– Ambient air-independent operation,
– A durable operating manual placed in a visible location near the boiler,
– The construction must include a protective device against mechanical damage (vehicle!) for the entire system (e.g. a bracket
or deflector).
3.3
Initial start-up
The technical staff can commission the ROTEX GSU after complete erection and connection.
3.4
Instruction and handover to the owner
The ROTEX GasSolarUnit is handed over to you after the technical staff have commissioned it. The installer will instruct you in
the servicing and operation of the ROTEX GSU at the time of handing over.
The instructions contain at least the following topics:
– Explanation of secure and proper use of the ROTEX GasSolarUnit as well as the legally imposed obligations, which are incum-
bent on you as the owner of a gas heating system,
– Explanation of the operating elements and the setting options which you can make,
– Explanation of the possible modes with reference to an economic and energy-saving operation,
– Explanation of the necessary cleaning and maintenance jobs which you can carry out,
– Action on malfunctions.
WARNING!
Improperly started ROTEX GasSolarUnit can cause damage to human life and health and impair its function.
• Only heating engineers, authorised and trained by gas and energy supply companies are allowed to start
up the ROTEX GSU.
The requirements and the tests before start up, starting up activities and the necessary tests are described in
detail in the installation and maintenance manual for expert operation.
The scope of delivery includes an installation and instruction form. Document proper handover by signing the
form along with the installer.