RKRTR + EKRTETS
Room thermostat
4PW56107-1
Installation manual
16
To enable floor protection, set the following codes:
To enable dew prevention, set the following codes:
1st
code
2nd
code
Description
Required
setting
Step
External temperature
sensor EKRTETS
installed?
ÌlË
—
Enable floor high/low
temperature limit?
ÌlË
—
Lower limit of floor
temperature
(a)
(a) Can be modified as preferred.
0.5°C
(a)
0.5°F
Upper limit of floor
temperature
(b)
(b) Default value. Can be modified as preferred.
0.5°C
(b)
0.5°F
NOTE
The dew prevention function can only be enabled if
floor temperature protection is enabled (refer to the
table above).
1st
code
2nd
code
Description
Required
setting
Step
Enable dew prevention
function?
ÌlË
—
Offset for dew point
calculation
0.1°C
0.2°F
Display result of dew
point calculation
Consult
only
—
Should condensation on the floor occur, we suggest
increasing field settings
and
. In case the
conditions are so extreme that this countermeasure
is not adequate, we suggest not to use floor cooling.