User manual

PART 4.  OPERATIONS AND FUNCTIONS

1.

SWING button/Wireless button

Used to initiate the AUTO SWING feature. When the operation is ON, press the SWING button can stop 
the louver at the desired angle.

Used to initiate the Wireless connection mode. For the first time to use Wireless function, press and 
hold the SWING button for 3 seconds to initiate the Wireless connection mode. The LED DISPLAY shows 
'AP' to indicate you can set Wireless connection. 

•  If connection (router) is successful within 8 minutes, the unit will exit Wireless connection mode 

automatically and the Wireless indicator illuminates.

•  If connection is failure within 8 minutes, the unit exits Wireless connection mode automatically. 

Under Wireless mode, you can press the swing and down(-) buttons at the same time for 3 seconds to 
turn off the Wireless and the LED DISPLAY shows 'OF' for 3 seconds , press the swing and up(+) buttons 
at the same time to turn on Wireless and the LED DISPLAY shows 'ON' for 3 seconds.

NOTE: 

When you restart the Wireless function, it may take a period of time to connect to the network 

automatically.

2.

FAN/ION button (Ion is optional)

Control the fan speed. Press to select the fan speed in four steps-LOW, MED (optional), HIGH and AUTO.
The fan speed indicator light illuminates under different fan settings except AUTO speed. When select 
AUTO fan speed, all the fan indicator lights turn dark. On some models, when select AUTO fan speed, 
all the fan indicator lights illuminate (optional).

NOTE: 

Press this button for 3 seconds to initiate ION  feature. The ION light illuminates. The ion 

generator is energized and will help to remove pollen and impurities from the air, and trap them in the 
filter. Press it for 3 seconds again to stop the ION feature.

3.

TIMER button

Used to initiate the AUTO ON start time and AUTO OFF stop time program, in conjuction with the + & -
buttons. The timer on/off indicator light illuminates under the timer on/off settings.

4.

SLEEP(Eco)/Filter button

Used to initiate the SLEEP/ECO operation.

NOTE: 

After 250 hours of operation, the filter indicator light illuminates. This feature is a reminder to 

clean the Air Filter for more efficient operation. Press this button for 3 seconds to cancel the reminder.

5.

MODE button

Selects the appropriate operating mode. Each time you press the button, a mode is selected in a 
sequence that goes from AUTO, COOL, DRY and FAN. The mode indicator light illuminates under the
different mode settings.

NOTE: On dry mode, you can adjust the humidity for models with humidity sensor.

1. BUTTON FUNCTIONS

Содержание ORTA O26W

Страница 1: ...ENG ORTA W Orta O26W User manual...

Страница 2: ...anel 15 PART 4 OPERATIONS AND FUNCTIONS 16 Button functions 16 Operations 17 Other features 18 Water drainage 19 PART 5 MAINTENANCE 21 Clean the filter 21 Clean the unit 21 Store the unit when not in...

Страница 3: ...costs D Products of this type contains valuable elements it can be sold sprzedane on purchase of metals Throwing the device on wild exposes you to the risk of losing your health Dangerous substances...

Страница 4: ...re not to use the wheels on thick carpet or to roll over objects as these could cause tipping DO NOT operate a unit that it has been dropped or damaged The appliance with electric heater shall have at...

Страница 5: ...oke comes from it Do not operate or stop the unit by inserting or pulling out the power cord plug Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the...

Страница 6: ...32 R290 Refrigerant only WARNING Thissymbolshowsthatthisapplianceusedaflammablerefrigerant Iftherefrigerant is leaked and exposed to an external ignition source there is a risk of fire CAUTION This sy...

Страница 7: ...sion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can...

Страница 8: ...current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere Replace components only with part...

Страница 9: ...vicing or decommissioning it is recommended good practice that all refrigerants are removed safely Whentransferringrefrigerantintocylinders ensurethatonlyappropriaterefrigerantrecoverycylindersareempl...

Страница 10: ...take 8 Drain outlet 9 Air outlet 10 Lower air filter 11 Lower air intake 12 Power plug socket 13 Power cord buckle 14 Power cord outlet 15 Bottom tray drain outlet 2 Fig 1 Fig 2 1 3 4 5 6 7 8 9 10 11...

Страница 11: ...rent The actual shape shall prevail The unit can be controlled by the unit control panel alone or with the remote controller This manual does not include Remote Controller Operations see the Remote Co...

Страница 12: ...e adaptor is aligned with the hole seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation 3 STEP THREE Preparing the Adjustable Window Slider Depend...

Страница 13: ...pe shorter Foam seal A Adhesive type Window slider A Window slider B if required Foam seal C Non adhesive type Foam seal C Non adhesive type 2 Screws Security Bracket Foam seal B Adhesive type shorter...

Страница 14: ...Installation Note Cover the hole using the adaptor cap when not in use Expansion anchor position Adaptor cap Wall Exhaust Adaptor B max 120cm or 47 inch min 30cm or 12 inch Fig 13 NOTE To ensure prope...

Страница 15: ...peed light optional 12 ION light 13 FOLLOW ME light 1 Fig 15 2 4 5 6 3 7 9 8 12 10 13 15 16 17 19 18 20 21 22 23 24 25 26 11 14 Id Element Function 14 LED display 15 Degrees Celsius 16 Degrees Fahrenh...

Страница 16: ...ress to select the fan speed in four steps LOW MED optional HIGH and AUTO The fan speed indicator light illuminates under different fan settings except AUTO speed When select AUTO fan speed all the fa...

Страница 17: ...one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is still present turn off the unit and unplug he power cord Contact the manufa...

Страница 18: ...t 1 hour increments up to 24 hours The control will count down the time remaining until start The system will automatically revert back to display the previous temperature setting if there is no opera...

Страница 19: ...ally operate power management feature The compressor will stop then the fan motor for some models may stop When the ambient temperature is higher than the setting temperature the unit will be automati...

Страница 20: ...nstalled firmly to prevent leakage When the water level of the bottom tray reaches a predetermined level the unit beeps 8 times the digital display area shows P1 At this time the air conditioning dehu...

Страница 21: ...ill to prevent blocked airflow due to animal hair Clean the unit using a damp lint free cloth and mild detergent Dry the unit with a dry lint free cloth 3 STORE THE UNIT WHEN NOT IN USE Drain the unit...

Страница 22: ...t connected or is blocked Turn off the unit disconnect the hose check for blockage and reconnect the hose The unit is low on refrigerant Call a service technician to inspect the unit and top off refri...

Страница 23: ...EEP display Displays when SLEEP function is activated 9 FOLLOW ME display Indicates that the FOLLOW ME function is on 10 FRESH AIR display Not available for this unit 11 SILENT display Not available f...

Страница 24: ...louver movement 7 SHORT CUT Sets and activates your favorite pre settings 8 TEMP Increases temperate in 1 C 1 F increments Max temperature is 30 C 86 F TEMP Decreases temperate in 1 C 1 F increments M...

Страница 25: ...match up the and ends of the batteries with the symbols inside the battery compartment 3 Slide the battery cover back into place NOTE For optimum product performance Do not mix old and new batteries o...

Страница 26: ...tart the unit NOTE FAN SPEED can t be changed in DRY mode 4 FAN operation 1 Press the MODE button to select FAN mode 2 Press FAN button to select the fan speed AUTO LOW MED or HIGH 3 Press the ON OFF...

Страница 27: ...t a period of time after which the unit will automatically turn off such as when you wake up 1 Press the TIMER OFF button By default the last time period that you set and an h indicating hours will ap...

Страница 28: ...hetimewillincreasein30minuteincrements with each press After 10 hours and up to 24 it will increase in 1 hour increments The timer will revert to zero after 24 hours You can turn off either function b...

Страница 29: ...perature from the remote control instead of from the indoor unit itself will enable the air conditioner to optimize the temperature around you and ensure maximum comfort 1 Press FOLLOW ME button to ac...

Страница 30: ...of purchase Indoor unit model Serial number Seller s stamp and signature Intaller s stamp and signature Sales data Invoice number Date of assembly Place of assembly Seller s stamp and signature I acc...

Страница 31: ...air conditioner 31 User manual Review date Service note Service stamp Signature 1 2 3 4 REGISTER FOR AIR CONDITIONERS PERIODIC REVIEWS Date of repair Service note Service stamp Signature 1 2 3 4 REGI...

Страница 32: ...www rotenso pl email info rotenso pl Installer stamp...

Отзывы: