PART 5. WIRED CONTROLLER SUPPORT
3. INSTALLATION METHOD
3.1. Simplified schematic of wire controller
E
B
A
D
C
E
B
A
D
C
RUN
GND
+5V
Indoor unit display panel
Transmitting tube
Indoor unit
Employ shielded 5-core wire for connection
the in here, the length should be set base
on field installation(<15m).
wire controller
3.2. Installation diagram
Fig. 3.1
Display panel
Connective wires for the display panel (accessory)
The shielded 5-core wire
pre-embedded into wall.
The shielded 5-core wire
pre-embedded into wall.
If there is no terminal,the 5-core wire should be connected directly.
1
2
3
4
Fig. 3.2
Fig. 3.3
Fig. 3.4
Fig. 3.5
1. Connect the male joint of 5-core wires group of the display panel with the female 5-core terminal of display
panel. (See Fig.3-2)
2. Please connect the other side of display panel with the wall pre-bedded 5-core cable reliability.
3. Connect the wire control leads from wire controller with the wall pre-bedde 5-core cable reliability. (See
Fig.3-3)
4. Take off the screws in the bottom cover of centralized controller by slotted head screw driver. (See Fig 3-4)
5. Adjust the length of two plastic bolts base on the length of through out from standard electric cabinet to
the wall. Confirm the two bolts fixing in the cabinet are in the same length and vertical to the wall surface.
6. Fix the bottom cover to the electric cabinet by the accessory slotted head screws. Confirm the bottom cover