Rotem RLD 7.2 Скачать руководство пользователя страница 9

 

9  

RLD 

|

 3.0/4.01 

1. Arrow keys:

 These keys change values of output voltage (in percentage) 

2. 

Channels:

 This specifies which channel is being dealt with. Note that the buttons are duplicated 

since each one is dedicated to each channel separately. 

3. 

Display:

 Both values of voltage and parameters are displayed here. 

4. 

Manual Dim:

 Pressing this button sets the RLD channel to manual mode. In manual mode you 

can set the light percentage using the arrow keys. Verify that you are changing the required channel.  

5. 

Bright:

 Pressing this button gradually increases the channel to full brightness for a period of 20 

minutes. Adjust the time period by pressing the up/down cursor keys. The display shows the 
remaining amount of time before the light begins to turn off. When this period ends, the decrease in 
light is gradual.    

6. 

Auto:

 Pressing this button utilizes the analog input card 0-10 V output or communication card and 

is controlled via a lighting table program. 

7. 

Off:

 Pressing this button gradually reduces the channel to 0% light intensity.  

8. 

Options:

 Press this button to view the RLD system parameters menu. 

Содержание RLD 7.2

Страница 1: ...RLD 7 2 RLD 14 Two Channel Light Dimmer Installation and User Manual P N 110036...

Страница 2: ...llowing cases i if all components of the product are not originally supplied by ROTEM ii the defect is the result of an act of nature lighting strikes electrical power surge or interruption of electri...

Страница 3: ...Bulb Type 10 4 1 2 System Parameter 2 Channel 10 4 1 3 System Parameter 3 Low Limit 11 4 1 4 System Parameter 4 Brightness Restriction 11 4 1 5 System Parameter 5 Ignition Pulse 11 4 2 Bright Mode 11...

Страница 4: ......

Страница 5: ...y other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury If you have any questions or comments regarding your...

Страница 6: ...rights reserved Document Number 110036 Revision Number 3 2 No part of this publication may be reproduced stored in an automated data file or made public in any form or by any means whether electronic...

Страница 7: ...e unique features such as stable operation in low brightness levels and high flexibility Main features Two independent channels Manual brightness control Programmable brightness control by analog sign...

Страница 8: ...old cathode ch Channel This parameter can receive values between 0 8 since it can be connected to 8 matching lines of the Platinum Plus AC 2000 controller Lo Low This parameter prevents lamps from bur...

Страница 9: ...Verify that you are changing the required channel 5 Bright Pressing this button gradually increases the channel to full brightness for a period of 20 minutes Adjust the time period by pressing the up...

Страница 10: ...se 4 1 1 System Parameter 1 Bulb Type The bu parameter defines the bulb type It is important to correctly define the type of bulb since each type has different electrical properties The options are Lb...

Страница 11: ...ghtness level some cold cathode and fluorescent bulbs require full power for a brief period of time milliseconds This option supplies the required power Since there are a large number of models on the...

Страница 12: ...nnect the RLD to a controller using one option only Connecting the RLD using both methods together results in faulty light levels Refer to Configuring the Channel Levels page 18 for information of con...

Страница 13: ...VAC 3600 VA 0 10 VDC Analog Input Impedance 10 KOhm Operating Temperature Range 0 to 60 C 32 to 140 F Humidity 85 Enclosure Water and dust tight IP66 Fuses Main Fuse 315 mA slow blow 5 1 Environmenta...

Страница 14: ...diagrams see below 3 To connect the 0 10 volt DC wire to the controller use two conductor 18 22 gauge cable Connect the minus to the Common terminal on the controller terminal block and the plus to te...

Страница 15: ...15 RLD 3 0 4 01 6 1 1 RLD 7 2 Wiring Figure 2 RLD 115V Single Phase Wiring Key 1 Neutral 2 115 VAC 3 Neutral 4 Safety ground...

Страница 16: ...RLD 3 0 4 01 16 Figure 3 RLED 115V Two Phase Wiring Key 1 Neutral 2 115 VAC Phase A 3 115 VAC Phase B 4 Neutral 5 Safety ground...

Страница 17: ...17 RLD 3 0 4 01 6 1 2 RLD 14 Wiring Figure 4 RLD 230V Single Phase Wiring Key 1 Neutral 2 230 VAC 3 Neutral 4 Safety ground...

Страница 18: ...ing sections detail how to configure the channel levels Using an Analog Output Card page 18 Using a Communication Card page 20 6 2 1 Using an Analog Output Card NOTE Verify that parameter ch is set to...

Страница 19: ...g Diagram Figure 7 RLD Board Version 1 3 1 to RAOC 8 Analog Output Wiring Diagram 2 To control both channels simultaneously short 0 10V A and 0 10V B 3 To configure the channel levels go to the o Anal...

Страница 20: ...here are two numbering options o Different numbers to each channel with up to 8 different channels when using multiple RLD units o Same number for more than one channel if you require the same behavio...

Страница 21: ...th 230 VAC 3 Check 5V 4 Check flat cable connection 2 Power is ON but there is no Output when working in AUTO mode with a 0 10V control voltage b RX TX communication lines 1 Make sure the and COM of 0...

Страница 22: ...3 Door Hinge SP RLD E 122044 SP RLD E 122044 4 Square Seal SP RLD E 200025 SP RLD E 200025 5 Flat Cable SP RLD E 141023 SP RLD E 141023 6 Fuses 0 1a 250V 5 20mm Bus s504 lf 218 190007 190004 7 RLD 72...