Rotem RLD 7.2 Скачать руководство пользователя страница 2

Warranty & Limitation of Liability 

1.  ROTEM warrants that the product shall be free of defects in materials or workmanship and will 
conform to the technical specification for a period of 1 (one) year from the date of initial installation on 
site (the "warranty period"). 

2.  ROTEM warrants that during said warranty period, any item/items or part/parts of equipment found 
defective with respect to materials or workmanship or which do not conform to the technical 
specification shall be repaired or replaced (at ROTEM's sole discretion), free of charge. 

3. During the warranty period, in the event of an alleged defect, authorized resellers in relevant regions 
should be notified  as soon as possible from the date of noticing the said defect, but no longer than thirty 
(30) days from such a discovery. The report shall include (1) a short description of the defects noticed 
(2) type of card / component and its matching serial number. 

4.  ROTEM's sole liability under this warranty is the repair or replacement of the defective item of 
product. 

5. Load cells are not covered by ROTEM’s warranty. 

Conditions and Limitations 

1. ROTEM will not be responsible for any labor costs or expenses associated with replacement of 
defective items or other parts of the product or repair. 

2.  This warranty shall not cover: (i) product or part therein which has been modified (without prior 
written approval of ROTEM), or (ii) product or part therein which has not handled or installed by an 
authorized reseller of ROTEM or (iii) product or part therein which has either handled or installed not 
in strict accordance with ROTEM's instructions, (iv) products which were used for function other 
than agriculture industry.  

3.  This warranty will not apply in the following cases: (i) if all components of the product are not 
originally supplied by ROTEM (ii) the defect is the result of an act of nature, lighting strikes, 
electrical power surge or interruption of electricity (iii) the defect is the result of accident, misuse, 
abuse, alteration, neglect, improper or unauthorized maintenance or repair. 

ROTEM  warns and alerts all users that the Product is inherently complex and may not be 
completely free of errors. ROTEM's products are designed and manufactured to provide reliable 
operation. Strict tests and quality control procedures are applied to every product. However, the 
possibility that something may fail beyond our control exists.  Since these products are 
designed to operate climate control and other systems in confined livestock environments, 
where failure may cause severe damage, the user should provide adequate backup and alarm 
systems.  These are to operate critical systems even in case of a ROTEM system failure.  
Neglecting to provide such a backup will be regarded as the user’s willingness to accept the risk 
of loss, injury and financial damage. 

In no event will ROTEM be liable to a user or any third party for any direct, indirect, special, 
consequential or incidental damages, including but not limited to any damage or injury to 
business earnings, lost profits or goodwill, personal injury, costs of delay, any failure of delivery, 
costs of lost or damaged data or documentation, lost or damaged products or goods, lost sales, 
lost orders, lost income. 

Except for the above express warranty, ROTEM makes no other warranties, express or implied, 
relating to the products. ROTEM disclaims and excludes the implied warranties of 
merchantability and fitness for a particular purpose. No person is authorized to make any other 
warranty or representation concerning the performance of the products other than as provided 
by ROTEM. 

Software Version:  

3.0/4.01 

Document Version:  

3.2 

 

Содержание RLD 7.2

Страница 1: ...RLD 7 2 RLD 14 Two Channel Light Dimmer Installation and User Manual P N 110036...

Страница 2: ...llowing cases i if all components of the product are not originally supplied by ROTEM ii the defect is the result of an act of nature lighting strikes electrical power surge or interruption of electri...

Страница 3: ...Bulb Type 10 4 1 2 System Parameter 2 Channel 10 4 1 3 System Parameter 3 Low Limit 11 4 1 4 System Parameter 4 Brightness Restriction 11 4 1 5 System Parameter 5 Ignition Pulse 11 4 2 Bright Mode 11...

Страница 4: ......

Страница 5: ...y other purpose or in a way not within the operating recommendations specified in this manual will void the warranty and may cause personal injury If you have any questions or comments regarding your...

Страница 6: ...rights reserved Document Number 110036 Revision Number 3 2 No part of this publication may be reproduced stored in an automated data file or made public in any form or by any means whether electronic...

Страница 7: ...e unique features such as stable operation in low brightness levels and high flexibility Main features Two independent channels Manual brightness control Programmable brightness control by analog sign...

Страница 8: ...old cathode ch Channel This parameter can receive values between 0 8 since it can be connected to 8 matching lines of the Platinum Plus AC 2000 controller Lo Low This parameter prevents lamps from bur...

Страница 9: ...Verify that you are changing the required channel 5 Bright Pressing this button gradually increases the channel to full brightness for a period of 20 minutes Adjust the time period by pressing the up...

Страница 10: ...se 4 1 1 System Parameter 1 Bulb Type The bu parameter defines the bulb type It is important to correctly define the type of bulb since each type has different electrical properties The options are Lb...

Страница 11: ...ghtness level some cold cathode and fluorescent bulbs require full power for a brief period of time milliseconds This option supplies the required power Since there are a large number of models on the...

Страница 12: ...nnect the RLD to a controller using one option only Connecting the RLD using both methods together results in faulty light levels Refer to Configuring the Channel Levels page 18 for information of con...

Страница 13: ...VAC 3600 VA 0 10 VDC Analog Input Impedance 10 KOhm Operating Temperature Range 0 to 60 C 32 to 140 F Humidity 85 Enclosure Water and dust tight IP66 Fuses Main Fuse 315 mA slow blow 5 1 Environmenta...

Страница 14: ...diagrams see below 3 To connect the 0 10 volt DC wire to the controller use two conductor 18 22 gauge cable Connect the minus to the Common terminal on the controller terminal block and the plus to te...

Страница 15: ...15 RLD 3 0 4 01 6 1 1 RLD 7 2 Wiring Figure 2 RLD 115V Single Phase Wiring Key 1 Neutral 2 115 VAC 3 Neutral 4 Safety ground...

Страница 16: ...RLD 3 0 4 01 16 Figure 3 RLED 115V Two Phase Wiring Key 1 Neutral 2 115 VAC Phase A 3 115 VAC Phase B 4 Neutral 5 Safety ground...

Страница 17: ...17 RLD 3 0 4 01 6 1 2 RLD 14 Wiring Figure 4 RLD 230V Single Phase Wiring Key 1 Neutral 2 230 VAC 3 Neutral 4 Safety ground...

Страница 18: ...ing sections detail how to configure the channel levels Using an Analog Output Card page 18 Using a Communication Card page 20 6 2 1 Using an Analog Output Card NOTE Verify that parameter ch is set to...

Страница 19: ...g Diagram Figure 7 RLD Board Version 1 3 1 to RAOC 8 Analog Output Wiring Diagram 2 To control both channels simultaneously short 0 10V A and 0 10V B 3 To configure the channel levels go to the o Anal...

Страница 20: ...here are two numbering options o Different numbers to each channel with up to 8 different channels when using multiple RLD units o Same number for more than one channel if you require the same behavio...

Страница 21: ...th 230 VAC 3 Check 5V 4 Check flat cable connection 2 Power is ON but there is no Output when working in AUTO mode with a 0 10V control voltage b RX TX communication lines 1 Make sure the and COM of 0...

Страница 22: ...3 Door Hinge SP RLD E 122044 SP RLD E 122044 4 Square Seal SP RLD E 200025 SP RLD E 200025 5 Flat Cable SP RLD E 141023 SP RLD E 141023 6 Fuses 0 1a 250V 5 20mm Bus s504 lf 218 190007 190004 7 RLD 72...

Отзывы: