background image

9

12 Volt Trigger Outlet 

]

   

Some audio components can be turned on 
automatically when they receive a 12V turn 
on “signal”. The 12V Trigger Outputs of the 
RA-03 provide the required signal. Connect 
compatible components to the RA-03 with a 
conventional 3.5mm miniplug cable. When the 
RA-03 is in Standby mode, the trigger signal 
is interupted, so the components controlled by 
it are turned off.

Protection Circuitry 

3

The RA-03 has both thermal and over-current 
protection circuitry that protects the amplifier 
against damage in the event of extreme or faulty 
operating conditions. The protection circuits 
are independent of the audio signal and have 
no impact on sonic performance. Instead, the 
protection circuits monitor the temperature of 
the output devices and shut down the amplifier 
if temperatures exceed safe limits.

Most likely, you will never see this protection 
circuitry in action. However, should a faulty 
condition arise, the amplifier will stop playing 
and the LED indicator on the front panel will 
light up.

If this happens, turn the amplifier off. Let it 
cool down for several minutes, and attempt to 
identify and correct the problem that caused 
the protection circuitry to engage. When you 
turn the amplifier back on, the protection circuit 
will automatically reset and the indicator LED 
should go out.

In most cases, the protection circuitry activates 
because of a fault condition such as shorted 
speaker wires, or inadequate ventilation lead-
ing to an overheating condition. In very rare 
cases, highly reactive or extremely low imped-
ance speaker loads could cause the protection 
circuit to engage.

If the protection circuitry triggers repeatedly 
and you are unable to isolate and correct the 
faulty condition, contact your authorized Rotel 
dealer for assistance in troubleshooting.

Troubleshooting

Most difficulties in audio systems are the result 
of incorrect connections, or improper control 
settings. If you encounter problems, isolate the 
area of the difficulty, check the control settings, 
determine the cause of the fault and make the 
necessary changes. If you are unable to get 
sound from the RA-03 refer to the suggestions 
for the following conditions:

Power Indicator Is Not Lit

The Power Indicator should be lit whenever the 
RA-03 is plugged into the wall power outlet 
and the Power Switch is pushed in. If it does 
not light, test the power outlet with another 
electrical device, such as a lamp. Be sure the 
power outlet being used is not controlled by 
a switch that has been turned off. 

Fuse Replacement

If another electrical device works when plugged 
into the power outlet, but the Power Indicator 
of the RA-03 does not light when plugged 
into the same outlet and the Power Switch is 
pushed in, it indicates that the internal power 
fuse may have blown. If you believe this has 
happened, contact your authorized Rotel dealer 
to get the fuse replaced. 

No Sound

Check the signal source to see if it is function-
ing properly. Make sure the cables from the 
signal source to the RA-03 inputs are connected 
properly. Be sure the Listening Selector is set 
to the proper input. Check the wiring between 
the RA-03 and the speakers. 

Specifications 

Continuous Power Output

 

60 watts/ch  

(20-20 kHz, < 0.03%, 8 ohms)

Total Harmonic Distortion (20Hz-20kHz)

 

< 0.03% at rated power, 1/2 power or 1 watt

Intermodulation Distortion (60 Hz : 7 kHz, 4:1)

  < 0.03% at rated power, 1/2 power or 1 watt

Frequency Response 

 

Phono Input

 

20Hz-15kHz, ±0.3dB 

 

Line Level Inputs

 

10Hz-100kHz, +1, –3dB

Damping Factor (20-20,000 Hz, 8 ohms)

 

180

Input Sensitivity / Impedance 

 

Phono Input

 

2.5mV / 47 kOhms 

 

Line Level Inputs

 

150 mV / 24 kOhms

Input Overload 

 

Phono Input

 

180mV 

 

Line Level Inputs

 

5V

Premp Output / Impedance

 

1V / 470 Ohms

Tone Controls - Bass / Treble

 

±6 dB at 100Hz / 10kHz

Signal to Noise Ratio (IHF “A” weighted) 

 

Phono Input

 

80 dB 

 

Line Level Inputs

 

100 dB

Power Requirements  

 

USA Version

 

115 Volts, 60 Hz 

 

European Version

 

230 Volts, 50 Hz

Power Consumption

 

300 W, 36 W - Idle, 3.7 W - Standby

Dimensions (W x H x D)

 

435 x 92 x 342 mm 

 

 

 

17

1

/

8

 x 3

5

/

8

 x 13

1

/

2

Panel Height

 

80 mm / 3

1

/

16

Weight (net)

 

7.7 kg, 17 lbs.

All specifications are accurate at the time of printing.  

Rotel reserves the right to make improvements without notice.

English

Содержание RA-03

Страница 1: ...pli er Ampli cateur Int gr St r ophonique Stereo Vollverst rker Ampli catore Integrato Estereofonico Ampli cador Integrado Estereof nico Ge ntegreerde Stereo Versterker Integrerad Stereof rst rkare RA...

Страница 2: ...eep the component away from radiators heat registers stoves or any other appliance that produces heat The unit must be connected to a power supply only of the type and voltage speci ed on the rear pan...

Страница 3: ...E RA 03 PHONES PROTECTION A OFF B A B TREBLE BASS BALANCE MONITOR SOURCE TAPE SPEAKERS OFF ON TONE POWER CD TUNER PHONO AUX 1 AUX 2 FUNCTION 1 3 2 4 5 6 7 8 9 0 q DOUBLE INSULATION When servicing use...

Страница 4: ...L NO RA 03 POWER CONSUMPTION 300W LEFT DO NOT OPEN NE PAS OUVRIR Figure 2 Signal Input and Speaker Output Connections Signaux d entr e et branchements enceintes acoustiques Signaleingang und Anschlu e...

Страница 5: ...been examined to ensure the most faithful music reproduction The main functions of the RA 03 are easy to install and use If you have experience with other stereo systems you shouldn t nd any thing pe...

Страница 6: ...cation Make sure that the shelf or cabinet can support it We recommend installing the RA 03 in furniture designed to house audio components Such furniture is designed to reduce or suppress vibration w...

Страница 7: ...there are times when both the A and B speakers will be used all the speakers should have an impedance of 8 ohms or more Speaker impedance ratings are less than precise In practice very few loudspeake...

Страница 8: ...Be particularly careful when turning the controls up clockwise This increases the power output in the bass or treble range increasing the load on the ampli er and speakers Function Control q s The Fu...

Страница 9: ...trol settings determine the cause of the fault and make the necessary changes If you are unable to get sound from the RA 03 refer to the suggestions for the following conditions Power Indicator Is Not...

Страница 10: ...1 3 5458 5310 Rotel of America 54 Concord Street North Reading MA 01864 2699 USA Phone 1 978 664 3820 Fax 1 978 664 4109 Rotel Europe Dale Road Worthing West Sussex BN11 2BH England Phone 44 0 1903 22...

Отзывы: