Set-Up Instructions

Follow these instructions to ensure a satisfactory set-up 

and operation of the lift.

•  After set-up and inspection of the lift, please return this 

booklet  to the literature package and give to lift owner/

operator.  Literature package should be kept attached to 

controls for easy access.

1.  Unloading:  Mobile Lift System units are shipped in the 

vertical position.

2.  After unloading, remove and discard protective 

wrapping. 

NOTE:  Unit is shipped without power unit 
fluid.  Installation of fluid MUST be completed 
prior to lift operation.

  Failure to do so will result 

in air entering the system.  The unit will then have to 

be bled.

3.  To move the column, remove protective banding and 

wheel clamps from wheel jack.  The forklift brackets can be 

removed from the side of the column if desired.

4.  Open power unit cover by removing the 3 M8 BHCS 

(Button Head Cap Screw).  Fill power unit tank with 

ISOAW32 hydraulic oil.  Tank capacity is approximately 11.5 

liters.  Short filling may cause vapor lock to occur.

5.  Connect two batteries in location shown, Fig. 1.    

Different batteries meeting the below specifications may be 

used but performance can vary.  

Recommended Battery Specifications:

12V DC Sealed Deep Cycle Battery

Size 24 Frame Group

80 AH Capacity (At 20 AH Rate)

Stud Terminals with Stainless Steel Wing nuts

Battery wires are clearly marked/labeled inside the unit 

itself.

Install tie-down straps on batteries as shown.  

Close lift and re-install M8 BHCS removed earlier.

After the batteries and fluid have been added

, screw M20 

bolt clockwise on wheel jack to adjust unloaded column 

ground clearance, Fig. 1.  Ground clearance is determined 

by how far the bolt is turned.  When the column is loaded, it 

will automatically lower to the floor.

WARNING  

 Permit only trained personnel to 

operate lift.  After reviewing these instructions, 

become familiar with the lift controls by running the lift 

through a few cycles before loading a vehicle on lift. 

Observe and heed SAFETY and WARNING labels on 

the lift.

                                                                           

WARNING  

 This motor has internal arcing or 

sparking parts.  To minimize the Risk of Explosion, DO 

NOT expose to flammable vapors.  

OPERATING CONDITIONS:  Lift is not intended for 

outdoor use or storage and has an operating ambient 

temperature range of 5º-40ºC.  This product is intended 

for indoor use only in a dry location.

DO NOT use lift in a manner other than intended.  

Included (but not limited to) examples of unapproved 

uses of the lift are: lifting vehicle by only one side, 

lifting different axles with a column pair (lifting on the 

diagonal), and lifting non-approved items. 

Set-Up Instructions  .................................................. 3

Safety Instructions  ................................................... 6

Owner/Employer Responsibilities  .......................... 6

Quick Start Operating Instructions  ........................ 8

Emergency Lowering .............................................. 11

Detailed Operating Instructions ............................ 12

Содержание HydroLift MC62

Страница 1: ...O N M A I N T E N A N C E Original Instructions Mobile Column Lift 24V DC Powered 4 Column Lift Capacity 24 800 kg 6 Column Lift Capacity 37 200 kg 6 200 kg per column IN161101N A IMPORTANT Reference...

Страница 2: ...t heavy vehicles for maintenance cleaning or repair to optimum working height Operation is carried out with a mobile control panel Lifting and lowering the vehicle is carried out in jog mode Electroni...

Страница 3: ...Battery Size 24 Frame Group 80 AH Capacity At 20 AH Rate Stud Terminals with Stainless Steel Wing nuts Battery wires are clearly marked labeled inside the unit itself Install tie down straps on batte...

Страница 4: ...e is 10 5mm per meter side to side of vehicle and 21 0mm per meter front to rear of vehicle DO NOT use on a suspended floor structure without specific approval from structural engineer Ensure tires ar...

Страница 5: ...enough to engage locks b Loosen bleed screw to release air from system c Close screw and repeat steps a and b until there is no air in the system and fluid runs clear Bleed Screw Do Not Exceed Torque...

Страница 6: ...d in the safe use and operation of the lift using the manufacturer s operating instructions ALI SM 07 1 ALI Lifting it Right safety manual ALI ST 05 ALI Safety Tips card ANSI ALI ALOIM 2008 American N...

Страница 7: ...interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inte...

Страница 8: ...was just placed The column will show Green when activated 5 Position next column at second wheel using loading instructions from step 3 6 Turn on second column Again using the Control Panel and the bu...

Страница 9: ...9 Fig 3 Fig 4 Fig 2 Power Up Switch...

Страница 10: ...olumns slowing down and speeding up at various stages of travel This is a normal characteristic of the lift leveling system Monitor the safety locks while raising the lift by listening for the mechani...

Страница 11: ...open Power Unit Cover Pull lock open Pull the Manual Lowering Valve Button and the carriage will begin lowering C If lift is on locks slightly lift carriage until lock is free D Lower each carriage a...

Страница 12: ...ed Red fast flash indicates a column with an error Operating Instruction Details Options Changing the System Configuration Columns may only be added to or removed from a system by unlocking the existi...

Страница 13: ...THE VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES CONTAIN SULFURIC ACID AND PRODUCE EXPLOSIVE GASES A BATTERY EXPLOSION COULD RESULT IN LOSS OF EYESIGHT OR SERIOUS BURNS FOR THIS REASON IT IS...

Страница 14: ...rriage for damage Monthly Check Emergency Stop Push the Emergency Stop button Columns should be inoperative with any emergency stop button depressed Monthly Lubrication 1 Lower lift check oil level in...

Страница 15: ...ess the buttons below in exact order until the error is generated 1 Up button Error Check replace contactor 2 Slow lower Error Check replace small lowering valve 3 Lower to locks Error Check replace l...

Страница 16: ...nnect switch is OFF if one is provided on the lift 3 The authorized lockout person operates the main energy isolation device removing power to the subject lift If this is a lockable device the authori...

Страница 17: ...Charger Red Black Black 12V Battery 12V Battery Ground String Pot Radio Wireless 2SWLRQDO Control PCB Buzzer Slow Valve Lock Solenoid Fast Valve Contactors Red White Black Bat Voltage Monitor Black B...

Страница 18: ...18 HYDRAULIC SCHEMATIC...

Страница 19: ...19 NOTES...

Страница 20: ...r for Genuine Rotary Replacement Parts See Literature Package for Parts Breakdown Rotary Lift Consolidated Haimen Co Ltd No 1388 East Xiushan Road Haimen Jiangsu Province China 226100 www vsg asia com...

Отзывы: