Issue 5
Original version
Nov 2014
6
3)
SPECIFICATION
Maximum hole cutting capacity in .2/.3C steel = 30mm dia. x 25mm deep
Arbor bore = 19.05mm (3/4”) dia.
Model
Voltage (V)(AC)
Normal Full Load
Watts (W)
SMARTPUMA1
110V 50-60Hz
800
SMARTPUMA3
230V 50-60Hz
800
Electro Magnet
Model
Voltage (V)(DC)
Normal Full Load
Amps (A)
Watts (W)
SMARTPUMA1
110
0.45
45
SMARTPUMA3
230
0.225
45
Total Normal Full Load ( motor)
845
Overall
Dimensions
Height (maximum extended)
410mm
Height (minimum)
360mm
Width (including Hand wheel)
170mm
Length Overall (including Guard)
250mm
Magnet Footprint
165mm x 80mm
Net Weight
11.20kgs
Stroke
With Arbor
With Drill chuck
30mm max
65mm
No Load
Speed
All voltages
600rpm
Tractive Force of Magnet at 20º C (25mm min. plate thickness)
The use on any material less than 25mm thick will progressively reduce the
magnetic performance. If possible substitute material should be positioned under
the magnet and work piece to equate to a suitable material thickness. If this is not
possible an alternative secure method of restraining the machine MUST be used.
8000N
Maximum hand/arm vibration magnitude (measured at handle during operation in
accordance with ISO5349 using a 22mm dia. cutter through 13mm mild steel plate.
2.95 m/s²
Estimate of vibration exposure. Operation 30 holes @ 1 minute/hole.
0.39 m/s² A(8)
Average noise level during cutting at operators ear position.
L
PA
Max. 88.3 dB(A)
L
WA
Max. 101.3dB(A)
Suitable only for a single phase 50-60 Hz A.C. power supply
DO NOT USE ON D.C. SUPPLY
Do not use your magnetic drill on the same structure when arc welding is in progress.
D.C. current will earth back through the magnet and cause irreparable damage.
WARNING: THIS APPLIANCE MUST BE EARTHED!
NB: ANY MODIFICATIONS TO THIS MACHINE WILL INVALIDATE THE GUARANTEE
List of Contents with Magnetic Dill Unit
Check
List
RD4329
Safety Strap
YES/NO
RD4088
4mm A/F Tee Handled Hexagon Key
YES/NO