Controller Functionality
58
AYC-x6355 (Rev. B) Installation and User Manual
7.9.14.4
Enrolling Primary and Secondary Codes using
Standard Method
To enroll primary and secondary codes using the Standard
method:
1.
Enter Programming mode.
2.
Press
7
to enter Menu 7.
The right LED turns orange.
3.
Enter the 3-digit user slot number between
001 and 500 that you wish to enroll a
Primary or Secondary code to.
For example, User Slot 003 represents User
#3.
If the selected slot has no Primary code, the
left LED flashes green, indicating that the
controller is ready to accept a Primary code.
If the selected slot already has a Primary code
but no Secondary code, the left LED flashes
red, indicating that the controller is ready to
accept a Secondary code.
If the selected slot already has a Primary and
Secondary code, you hear a long beep and
the controller returns to Normal mode.
4.
Perform one of the following:
Enter the 4- to 8-digit PIN code that you
want to assign as the Primary or
Secondary code for this slot number.
Present your user card that you want to assign as the Primary
or Secondary code for this slot number.
Green
Orange
Green Orange
Red Orange
Green