Technical Specifications
AYC-x6355 (Rev. B) Installation and User Manual
11
2.
Technical Specifications
Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
AYC-H/M6355: Standby: 120 mA, max: 160 mA
AYC-Q6355: Standby: 145 mA, max: 200 mA
Read Range*
AYC-H/M6355: 9 cm (3.5 in.)
AYC-Q6355: 5 cm (2.5 in.)
Green LED Control
Dry Contact, N.O.
Red LED Control
Dry Contact, N.O.
Buzzer Control
Dry Contact, N.O.
Tamper Output
Open collector, active low, max. sink current
16 mA
Maximum Cable Distance
to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable
Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity
Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, epoxy-potted,
suitable for indoor and outdoor use
* Measured using a Rosslare MIFARE Classic EV1 (ISO card). Read range with
other credential technologies may vary. Range also depends on electrical
environment and proximity to metal.