Controller Functionality
40
AYC-x6355 (Rev. B) Installation and User Manual
7.2.4.3
Changing from Normal Mode to Bypass Mode
See Section
7.9.7 to create/modify the Normal/Bypass code.
To change from Normal to Bypass mode:
1.
Enter the Normal/Secure code.
The left LED flashes orange.
2.
Press
#
to confirm the mode change.
The left LED stops flashing.
7.2.4.4
Changing from Bypass Mode to Normal Mode
See Section
7.9.7 to create/modify the Normal/Bypass code.
To change from Bypass to Normal mode:
1.
Enter the Normal/Secure code.
The left LED flashes green.
2.
Press
#
to confirm the mode change.
The left LED stops flashing.
7.3
Auxiliary Input and Output
For optimum usability in different applications, the controller’s
auxiliary input and output can be configured in ten different modes of
operation.
7.4
Door Alarms
Door alarms can be generated by connecting the Auxiliary Input to a
Door Position Switch. Either Door-Forced or Door-Ajar conditions are
supported, as well as, a configurable delay timer for each alarm type.
Only one door alarm is enabled at any one time. Door alarms may
activate auxiliary output and siren depending on the auxiliary settings.
Green
Orange
Orange
Orange
Green
Green