Reader Functionality
AYC-E/Q60 Family Instruction Manual
21
5.
Reader Functionality
The AYC-E/Q60 series can function both as a reader and as a
controller. If the unit is connected to standard access controller, it
functions as a reader, indicated by one beep immediately after power-
on reset.
The following explains how the AYC-E/Q60 series functions as a
reader.
5.1
Transmit Mode
When the AYC-E/Q60 is in Transmit Mode, it is ready to receive data
from a presented Proximity Card or an entered PIN code.
When the reader is in Transmit
Mode, the Transmit LED is red and
the Program LED is off.
When a Proximity Card or Keyboard entry is being transmitted, the
Transmit LED flashes green.
Keyboard data can be sent via one of eight different Keypad
Transmission Formats. For more information, see Section
Proximity Cards presented to the reader are always sent in either
Wiegand, Clock & Data or, Wiegand Card + PIN format. See Section
5.2.5 for more information.
5.2
Programming the AYC-E/Q60 Series
Programming the AYC-E/Q60 series is done solely via the unit's
keypad driven Programming Menu System. To reach the Programming
Menu System the AYC-E/Q60 must first be placed into Programming
Mode. During the AYC-E/Q60’s manufacturing process, certain codes
and settings are pre-programmed. These settings are called the
Default Factory Settings.
Mode/Transmit
Door/Program
Red