background image

Wiring Instructions 

AY-R12 Installation Manual 

11 

4.

 

Trim and cover all unused conductors. 

 

 

The individual wires from the reader are color-coded according the 
Wiegand standard. 

 

When using a separate power supply for the reader, this supply and 
that of the controller, must have a common ground. 

 

The reader’s cable shield wire should preferably be attached to an 
earth ground, or a signal ground connection at the panel, or power 
supply end of he cable. This configuration is best fro shielding the 

Reader cable from external interference 

 
 

Содержание AY-R12

Страница 1: ...AY R12 Outdoor RGB Illuminated Reader Installation Manual ...

Страница 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Страница 3: ...Installation Manual iii Table of Contents 1 Introduction 7 1 1 Features 7 2 Technical Specifications 8 3 Mounting Instructions 9 4 Wiring Instructions 10 5 Operating Instructions 12 6 Testing the Reader 13 A Limited Warranty 14 ...

Страница 4: ...List of Figures iv AY R12 Installation Manual List of Figures Figure 1 Mounting Template 9 ...

Страница 5: ...List of Tables AY R12 Installation Manual v List of Tables Table 1 Wiring Colors 10 Table 2 Operations Table 12 ...

Страница 6: ...ore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in the manual are for t...

Страница 7: ...5 225 425 525 panels AC 015 AC 020 and AC 115 controllers and AxTraxNG software as well with any third party controllers that support the same Wiegand input The panel links are used to set various conditions between events and outputs to get the required illumination from the reader 1 1 Features Stylish and practical application to add color to any environment enabling a high quality high tech atm...

Страница 8: ...nt 16 mA Read Range max 8 cm 3 2 in Maximum Cable Distance to Controller 150 m 500 ft RE Modulation ASK 125 kHz Regulatory Approvals CE Environmental Characteristics Operating Temp Range 31 C to 63 C 25 F to 145 F Operating Humidity Range 0 to 95 non condensing Physical Characteristics Height x Width x Depth 120 x 89 x 21 mm 4 7 x 3 5 x 0 8 in Weight 202 g 7 1 oz Measured using a Rosslare proximit...

Страница 9: ...e reader 1 Determine an appropriate mounting position for the reader 2 Screw off the back of the unit and place it at the desired mounting position 3 Using the template as a guide drill two holes hole size is indicated on mounting template for mounting the reader to the surface Figure 1 Figure 1 Mounting Template 4 Drill a 10 mm 7 16 hole for the cable 5 Route the interface cable from the reader t...

Страница 10: ...the wires 1 3 cm 2 Prepare the controller cable by cutting its jacket back 3 2 cm 1 and stripping the wires 1 3 cm 3 Splice the reader s pigtail wires to the corresponding controller wires and cover each connection Table 1 Wiring Colors Color Wiring Black Ground Red Vin Green Data 0 White Data 1 Brown G LED Purple Tamper Yellow SET 0 Blue SET 1 Gray SET 2 Orange SET 3 If the tamper output is being...

Страница 11: ... standard When using a separate power supply for the reader this supply and that of the controller must have a common ground The reader s cable shield wire should preferably be attached to an earth ground or a signal ground connection at the panel or power supply end of he cable This configuration is best fro shielding the Reader cable from external interference ...

Страница 12: ... Set 1 Set 2 Set 3 Green 0 0 0 0 Green with dimming 0 0 0 1 Red 0 0 1 0 Red with dimming 0 0 1 1 Blue 0 1 0 0 Blue with dimming 0 1 0 1 Purple 0 1 1 0 Purple with dimming 0 1 1 1 Yellow 1 0 0 0 Yellow with dimming 1 0 0 1 Light Blue 1 0 1 0 Light Blue with dimming 1 0 1 1 White 1 1 0 0 White with dimming 1 1 0 1 No Illumination 1 1 1 0 7 colors circularly with dimmer 1 1 1 1 1 Not connected 0 Conn...

Страница 13: ...er which the LED lights up green according to Set 0 Set 1 Set 2 and Set 3 setup This indicates that the reader is working properly The default is that the reader switches colors circularly The color can be set according to the input wires 2 Present the appropriate type of proximity card to the reader The LED turns green if set to default and a short beep is emitted indicating that the card was rea...

Страница 14: ...d Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Страница 15: ...osslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electron...

Отзывы: