Table of Contents 

AC-x32 Series Installation and Programming Manual 

iii 

Table of Contents 

1.

 

Introduction ................................................................ 8

 

1.1

 

Reader/Controller Types........................................................... 8

 

1.2

 

Equipment .............................................................................. 8

 

1.3

 

Additional Equipment .............................................................. 9

 

2.

 

Technical Specifications ............................................ 10

 

3.

 

Installation ................................................................ 12

 

3.1

 

Mounting ............................................................................. 12

 

3.2

 

Wiring .................................................................................. 14

 

3.2.1

 

AC-B32 ......................................................................................... 14

 

3.2.2

 

AC-C32 ........................................................................................ 15

 

3.2.3

 

AC-D32 ........................................................................................ 16

 

4.

 

Operation .................................................................. 17

 

4.1

 

User Levels ............................................................................ 17

 

4.2

 

Modes of Operation .............................................................. 18

 

4.2.1

 

Normal Mode ............................................................................... 18

 

4.2.2

 

Bypass Mode ................................................................................ 18

 

4.2.3

 

Secure Mode ................................................................................ 18

 

4.3

 

Changing the Modes of Operation ......................................... 19

 

4.3.1

 

Changing from Normal to Secure Mode ....................................... 19

 

4.3.2

 

Changing from Secure to Normal Mode ....................................... 19

 

4.3.3

 

Changing from Normal to Bypass Mode ....................................... 20

 

4.3.4

 

Changing from Bypass Mode to Normal Mode ............................. 20

 

4.4

 

REX Button ........................................................................... 20

 

4.5

 

Case and Back Tampers ......................................................... 21

 

Содержание AC Series

Страница 1: ...AC x32 Series Standalone Access Control Units Installation and Programming Manual AC B32 AC C32 AC D32 ...

Страница 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Страница 3: ...iring 14 3 2 1 AC B32 14 3 2 2 AC C32 15 3 2 3 AC D32 16 4 Operation 17 4 1 User Levels 17 4 2 Modes of Operation 18 4 2 1 Normal Mode 18 4 2 2 Bypass Mode 18 4 2 3 Secure Mode 18 4 3 Changing the Modes of Operation 19 4 3 1 Changing from Normal to Secure Mode 19 4 3 2 Changing from Secure to Normal Mode 19 4 3 3 Changing from Normal to Bypass Mode 20 4 3 4 Changing from Bypass Mode to Normal Mode...

Страница 4: ... Strike Release Time 28 5 9 Enrolling Primary and Secondary Codes 29 5 9 1 Primary Codes 29 5 9 2 Secondary Codes 30 5 9 3 Enrolling Primary and Secondary Codes 30 5 9 4 Enrolling Primary and Secondary Codes Using the Standard Method 30 5 9 5 Enrolling Secondary Codes Using the Code Search Method 32 5 10 Deleting Primary and Secondary Codes 33 5 10 1 Deleting Primary and Secondary Codes Using the ...

Страница 5: ...s 13 Figure 3 AC D32 Mounting Holes and Terminal Blocks 13 Figure 4 AC B32 Wiring the Lock Strike Relay and REX 14 Figure 5 AC B32 Wiring the BL D40 External Sounder 14 Figure 6 AC C32 Wiring the Lock Strike Relay and REX 15 Figure 7 AC C32 Wiring the BL D40 External Sounder 15 Figure 8 AC D32 Wiring the Lock Strike Relay and REX 16 Figure 9 AC D32 Wiring the BL D40 External Sounder 16 ...

Страница 6: ...List of Tables vi AC x32 Series Installation and Programming Manual List of Tables Table 1 Programming Menu 23 ...

Страница 7: ...f the system with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncomplianc...

Страница 8: ...g a proximity card 1 1 Reader Controller Types The six types of units described in this manual are Keypad Type PIN Proximity AC B32 3X4 Standard AC C32 2X6 Mullion AC D32 3X4 Standard 1 2 Equipment The following equipment is provided in every AC x32 package AC x32 controller Installation kit 1 drilling template label sticker 1 security spline key 1 security hex screw 4 mounting screws and wall plu...

Страница 9: ... Power to Lock or Fail Secure Power to Open Power supply with backup battery 12 to 16 VDC from a regulated power supply Request to Exit REX button Normally Open Type switch is closed when pressed BL D40 External Sounder optional Provides siren bell and chime functions to the controller Other Rosslare accessories can be found at Rosslare s website http www rosslaresecurity com ...

Страница 10: ...uts Lock Strike Relay Electronic 3 5 A with built in suppressor protection Auxiliary Relay Form C 1 A Inputs REX N O Dry Contact Auxiliary Input In Monitor Monitor Mode N C Dry Contact Input Mode N O Dry Contact LEDs Two tri colored LEDs Built In Proximity Reader Read Range 90 mm 3 5 in Modulation ASK at 125 kHz Compatible cards All 26 Bit EM cards Measured using a Rosslare proximity card or equiv...

Страница 11: ...e 31 C to 63 C 25 F to 145 F Operating Humidity Range 0 to 95 non condensing Physical Characteristics Dimensions Length x Width x Depth AC B32 92 x 92 x 24 mm 3 6 x 3 6 x 0 9 in AC C32 130 x 42 x 18 mm 5 1 x 1 7 x 0 7 in AC D32 122 x 75 x 24 mm 4 8 x 3 0 x 0 9 in Weight AC B32 124 g 4 4 oz AC C32 55 g 1 9 oz AC D32 115 g 4 1 oz ...

Страница 12: ...t shoulder height and on the same side as the door handle The AC x32 is designed to be easily mounted onto a US Gang Box To mount the controller 1 Peel off the back of the self adhesive mounting label template and place it on the required mounting location 2 At the bottom of the unit s case remove the screw 3 Carefully remove the snap off front cover of the unit to reveal the screw holes 4 Screw t...

Страница 13: ...crew the back plate into the surface Ensure the screws are the size specified on the installation template The unit can also be mounted using strong epoxy glue After application firmly hold the unit in place until the glue dries 7 Carefully re attach the front cover of the unit 8 Secure the front cover by using the supplied security Torx screw A Torx security screw tool is provided to tighten the ...

Страница 14: ...tion and Programming Manual 3 2 Wiring Typical wiring diagrams for the various units are shown in the following subsections 3 2 1 AC B32 Figure 4 AC B32 Wiring the Lock Strike Relay and REX Figure 5 AC B32 Wiring the BL D40 External Sounder ...

Страница 15: ...Installation AC x32 Series Installation and Programming Manual 15 3 2 2 AC C32 Figure 6 AC C32 Wiring the Lock Strike Relay and REX Figure 7 AC C32 Wiring the BL D40 External Sounder ...

Страница 16: ...Installation 16 AC x32 Series Installation and Programming Manual 3 2 3 AC D32 Figure 8 AC D32 Wiring the Lock Strike Relay and REX Figure 9 AC D32 Wiring the BL D40 External Sounder ...

Страница 17: ... are three user levels Normal User A Normal User only has a Primary code and is only granted access when the unit is in Normal or Bypass mode Secure User A Secure User must have a Primary and Secondary code programmed the two codes cannot be the same The Secure User can gain access when the unit is in any of its three modes of operation In Normal mode the Secure User must use a Primary code to gai...

Страница 18: ...rogrammed for Fail Safe Operation or for Fail Secure Operation When the Lock Strike Relay is programmed for Fail Secure Operation the door is locked until the doorbell button is pressed When the Lock Strike Relay is programmed for Fail Safe Operation the door is constantly unlocked 4 2 3 Secure Mode The Mode LED is red Only Secure and Master Users can access the premises during the Secure Mode A S...

Страница 19: ...nter the 4 digit Normal Secure code The Mode LED flashes red 2 Press to confirm the mode change The Mode LED turns red 4 3 2 Changing from Secure to Normal Mode The default factory setting for the Normal Secure Code is 3838 To change from Secure to Normal mode 1 Enter the 4 digit Normal Secure code The Mode LED flashes green 2 Press to confirm the mode change The Mode LED turns green Mode Door Red...

Страница 20: ... Bypass code The Normal Bypass code must first be programmed to use this function see Section 5 6 to create modify the Normal Bypass Code To change from Bypass to Normal mode 1 Enter the 4 digit Normal Bypass code The Mode LED flashes green 2 Press to confirm the mode change The Mode LED turns orange 4 4 REX Button The REX button is used to open the door without the use of a PIN code and must be l...

Страница 21: ...wer supply or another compatible device One of these devices then activates a siren and if available a strobe light The siren time can be easily programmed in the unit from 0 to 9 minutes You can clear a tamper event by entering a valid User or Open code to open the Lock Strike Output in the current mode of operation For example while in Secure mode you cannot use the Open code to clear the tamper...

Страница 22: ...e case of the controller is opened or when the controller is removed from the wall The controller can also program the length of the siren in the BL D40 The controller communicates with the BL D40 using a coded proprietary Rosslare communications protocol This provides a more secure link between the controller and the BL D40 If the BLD40 receives any unrecognized codes on its communication line or...

Страница 23: ...s Table 1 shows the names of all the unit s menus It also shows all the default factory codes and settings Table 1 Programming Menu Menu Number Menu Description Factory Settings 1 Change Open Code 1 2580 2 Change Open Code 2 0852 3 Change Program Code 1234 4 Change Normal Secure Code 3838 5 Change Normal Bypass Code N A 6 Change Door Release Time 0004 7 Enroll PIN code proximity cards or both N A ...

Страница 24: ...ramming code If the Programming code is valid the Door LED turns green and the unit enters Programming mode 5 2 Exiting Programming Mode Wrong entries may reset the controller back to Normal mode While in Programming mode if no key is pressed for one minute the unit exits Programming mode and returns to Normal mode In certain Programming modes a quick press on may also return the system to Normal ...

Страница 25: ...ivates Open Code 1 To change the Open Code 1 1 Enter Programming mode 2 Press 1 to enter Menu 1 The Mode LED turns red 3 Enter the new 4 digit Open Code 1 code The system returns to Normal mode 5 4 Changing Open Code 2 Open Code 2 is mainly used as a method to quickly test the Lock Strike Relay during installation The default factory setting for Open Code 2 is 0852 When the first user is added to ...

Страница 26: ...ormal mode 5 5 Changing the Programming Code The Programming code cannot be erased code 0000 is invalid and does not erase the Programming code To change the Programming code 1 Enter Programming mode 2 Press 3 to enter Menu 3 The Mode LED turns green 3 Enter the new 4 digit Programming code Three beeps are emitted The system returns to Normal mode Mode Door Green Mode Door Orange Green Mode Door G...

Страница 27: ...igit Normal Secure code Three beeps are emitted The system returns to Normal mode 5 7 Changing the Normal Bypass Code and Door Chime Settings The Normal Bypass code is also used to turn the door chime off and on The door is only generated when the Lock Strike Relay is activated due to a valid code entry To change the Normal Bypass code and Door Chime Settings 1 Enter Programming mode 2 Press 5 to ...

Страница 28: ... chime Enter the code 0001 Enable Bypass Code and disable the door chime Enter any code ending with 0 Enable Bypass Code and enable the door chime Enter a code not ending with 0 Three beeps are emitted The system returns to Normal mode 5 8 Setting Fail Safe Secure Operation Tamper Siren Time and Lock Strike Release Time 1 Enter Programming mode Press 6 to enter Menu 6 The Mode LED flashes green Mo...

Страница 29: ...s a Fail Secure Operation consisting of a 5 minute siren and a 12 second Lock Strike release time Three beeps are emitted The system returns to Normal mode 5 9 Enrolling Primary and Secondary Codes 5 9 1 Primary Codes Primary Codes can only be enrolled to an empty user slot meaning a slot where there is no existing Primary code Primary Codes must be unique meaning that one user s Primary Code cann...

Страница 30: ...ere are two methods to enroll Primary and Secondary codes Standard Method Mainly used when the user slot number for the user that you want to program is known You can program both Primary and Secondary codes using the Standard method see Section 5 9 4 Code Search Method Mainly used when enrolling a user s Secondary code and the User slot code is unknown The Code Search method only works if a user ...

Страница 31: ...e controller is ready to accept a Secondary Code If the selected slot already has a Primary and Secondary Code you hear a long beep and the controller returns to Normal mode b Present a proximity card or enter the 4 digit PIN that you want to assign as the Primary or Secondary Code for this slot number If the proximity card presented or PIN entered is valid the Mode LED stops flashing and the cont...

Страница 32: ... whom you want to add a Secondary Code 4 Present a proximity card or enter the 4 digit PIN code of the Primary code belonging to the user for whom you want to add a Secondary code 5 The Mode LED flashes red If the Primary code entered is not valid a long beep is emitted and the unit continues to wait for a valid Primary code 6 Present a proximity card or enter the 4 digit PIN code to be used as th...

Страница 33: ...hich user slots are empty and which user slots are not 5 10 1 Deleting Primary and Secondary Codes Using the Standard Method To delete the Primary and Secondary codes using the Standard Method 1 Enter Programming mode 2 Press 8 to enter Menu 8 The Mode LED turns orange and the Mode LED turns red 3 Enter the 3 digit user slot code you wish to delete The Mode LED flashes red indicating the controlle...

Страница 34: ...ord be kept of added and deleted users so that it is easier to keep track of which user slots are empty and which user slots are not To delete the Primary and Secondary codes using the Code Search Method 1 Enter Programming mode 2 Press 8 to enter Menu 8 The Mode LED turns orange and the Mode LED turns red 3 Enter 000 as the 3 digit user slot number The Door LED flashes orange indicating that the ...

Страница 35: ...ings Be very careful before using this command as it erases the entire memory including all User and Special codes and returns all codes to their factory default settings To return to factory default settings 1 Enter Programming mode 2 Press 0 to enter Menu 0 The Mode LED and the Door LED flash red 3 Enter your 4 digit Programming code If the Programming Code is valid all memory is erased three be...

Страница 36: ... program a new Programming code into the unit using the initial default code 1234 before the controller reverts to the existing code 5 13 Replacing a Lost Normal Secure Code To be able to replace lost Normal Secure code the controller must be in Secure mode Before proceeding verify that the Mode LED is red 1 Remove power from the unit 2 Press the REX button 3 Apply power to the unit while pressing...

Страница 37: ... 37 A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Страница 38: ...ort na rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare ...