Page 14

06/01

06/01

Request to Exit (REX) Button

Case and Back Tamper

The REX button must be located inside the premises to be secured
and is used to open the door without the use of a proximity card or
PIN code, it is usually located in a convenient location, e.g. Inside
the door or at a receptionist's desk. The function of the REX button
depends on whether the Lock Strike Relay is programmed for Fail
Safe Operation or Fail Secure Operation. The door chime in the BL-
D40 does not sound when the REX button is used to open the door.

Fail Secure Operation: From the moment the REX button is

pressed, the door will be unlocked until the "Lock Strike Release
Time" has passed. After this time, the door will be locked even if
the REX button has not been released.

Fail Safe Operation: From the moment the REX button is

pressed, the door will be unlocked until the REX button is
released, plus the "Lock Strike Release Time". In this case the
"Lock Strike Relay" only begins its count down once the REX
button has been released.

If the case of the controller is opened or the controller is removed
from the wall, a tamper event is triggered and a coded tamper
signal is sent to a BL-D40, PS-X41 Series or PS-X42 Series Power
Supply, or other compatible device.

If the BL-D40 External Sounder , PS-X41 Series or PS-X42 Series
Power Supplies receive a Tamper Event Signal, they will activate a
Siren and if available a Strobe Light. The Siren time can be easily
programmed in the AC-C31 from 0 to 9 minutes.

Clearing a tamper event is done by entering a valid User or Open
Code that will open the Lock Strike Output in the current Mode of
Operation. For example, while in Secure Mode, using the Open
Code to clear tamper event will not work because the Open Code
does not work in Secure Mode. However, applying a Master Code
or Secure Code will clear the tamper event in Secure Mode.

1)

2)

BL-D40 External Sounder

The BL-D40 External Sounder is compatible with the AC-X31, AC-
X32, AC-X41, and AC-X42 series Standalone Controllers (For a
more up-to-date list of compatible products check the Rosslare Web
Site at www.rosslare.com.hk). It is designed to operate indoors and
installed within the premises to be secured. The Sounder can be
powered by 16V AC or 12 to 24V DC power supply.

The BL-D40 is capable of emitting four different types of alerts both
audible and visual; Bell, Door Chime, Siren, and Strobe Light.

The Bell always sounds when the controller's doorbell button
is pressed.

The Door Chime can be programmed to sound whenever the

controller unlocks the door (the Door Chime does not sound
when the REX button is used to open the door).

The Siren can be programmed to sound when the case of the
controller is opened or when the controller is removed from the
wall. The controller can also program the length of the Siren in
the BL-D40.

The Controller communicates with the BL-D40 using a coded
proprietary Rosslare communications protocol. This provides a
more secure link between the Controller and the BL-D40. If the BL-
D40 receives any unrecognized codes on its communication line or
communication between the controller and the BL-D40 are severed,
the Strobe with flash repeatedly until the communication problem
has been resolved.

1)

2)

3)

Page 15

AC-C31

AC-C31

Содержание AC-C31

Страница 1: ...ROSSLARE INSTRUCTION MANUAL AC C31 STAND ALONE ACCESS CONTROL UNIT 08 01 9J IDR 016 A 0706 0820016 01 ROSSLAR E www rosslare com hk ROSSLAR E 1 2 3 4 5 6 7 8 9 0 MODE DOOR 3 4 ...

Страница 2: ...28 Replacing a lost Programming Code 29 Replacing a lost Normal Secure Code 29 Glossary 30 INTRODUCTION INSTALLATION FEATURES AND CONCEPTS PROGRAMMING THE AC C31 APPENDIX TECHNICAL SUPPORT 3 6 16 33 AC C31 Introduction Equipment provided The following is provided as part of every AC C31 package The AC C31 is a keypad access control unit The unit accepts up to 500 users and provides entry via the u...

Страница 3: ...lbs 70g Page 4 AC C31 Page 5 06 01 Key Features Here are some of the AC C31 s key features Built in Keypad for PIN code entry Internal Buzzer Comes with security screw and security screw tool Two Status Programming Interface LED s Three User Levels Normal User Secure User Master User Three Modes of Operation Normal Mode Bypass Mode Secure Mode Code Search feature makes maintaining user codes easie...

Страница 4: ...entry holes and attach them to the controllers terminal blocks as shown in the wiring diagrams Wiring diagrams for common installations can be found on pages 10 to 12 Replace the controller s bezel and replace the factory default screw with the security screw that is provided in the Installation Kit A security screw tool is also provided in the Installation Kit A few of the typical wiring diagrams...

Страница 5: ...RIC LOCK STRIKE FAIL SAFE or FAIL SECURE REX COMMON POWER SUPPLY 12V 16V DC Lock REX BL Lock REX BL AC C31 Wiring the BL D40 External Sounder 06 01 Page 9 AC C31 COMMON POWER SUPPLY 12V 16V DC REX BL BL D40 1 2 3 4 5 6 7 8 9 0 MODE DOOR AC C31 1 2 3 4 5 6 7 8 9 0 MODE DOOR REX BL ...

Страница 6: ...onvenient but is less secure than a Secure User There are three user levels Normal User Secure User Master User Modes of Operation The AC C31 has 3 Modes of Operation 1 Normal Mode 2 Bypass Mode 3 Secure Mode Mode LED is green Normal Mode is the default mode In Normal Mode the door is locked until a Primary Code is presented to the controller Special codes such as Open Code 1 and Open Code 2 are a...

Страница 7: ... will turn green 1 2 1 2 Changing from Normal Mode to Bypass Mode Changing from Bypass Mode to Normal Mode See Page 20 to create modify the Normal Bypass Code Enter the 4 digit Normal Bypass Code Mode LED will flash orange Press the key to confirm the Mode change Mode LED will turn orange See Page 20 to create modify the Normal Bypass Code Enter the 4 digit Normal Bypass Code Mode LED will flash g...

Страница 8: ...by entering a valid User or Open Code that will open the Lock Strike Output in the current Mode of Operation For example while in Secure Mode using the Open Code to clear tamper event will not work because the Open Code does not work in Secure Mode However applying a Master Code or Secure Code will clear the tamper event in Secure Mode 1 2 BL D40 External Sounder The BL D40 External Sounder is com...

Страница 9: ... Menu Page 16 06 01 AC C31 Page 17 06 01 Entering Programming Mode Exiting Programming Mode 1 2 Note 1 2 3 4 Press the key for 2 seconds Mode LED will turn off Door LED will turn red Enter your 4 digit Programming Code If the Programming Code is valid the door LED will turn green and the AC C31 will be in Programming Mode The AC C31 must be in Normal Mode to enter the Programming Mode The factory ...

Страница 10: ...fault Open Code will automatically be deleted ready for a new Open Code 2 to be re entered 1 2 1 Menu 1 3 4 Note Page 18 08 01 AC C31 Page 19 06 01 1 2 2 Menu 2 3 4 Note 1 2 3 Menu 3 3 4 Note Enter Programming Mode Press to enter The Mode LED will turn red Enter the new 4 digit code you wish to set as Open Code 2 System returns to Normal Mode You will hear three beeps The Door LED will turn off Th...

Страница 11: ...al Bypass Code and Door Chime can be programmed Disable Bypass Mode Disable Door Chime Disable Bypass Mode Enable Door Chime Enable Bypass Mode Disable Door Chime Enable Bypass Mode Enable Door Chime Page 20 06 01 AC C31 Page 21 06 01 a b c d 4 Note Disable Bypass Code Disable Door Chime Disable Bypass Code Enable Door Chime Enable Bypass Code Disable Door Chime Enable Bypass Code Enable Door Chim...

Страница 12: ...m is known You can program both Primary and Secondary Codes using the Standard method See Enrolling Users with the Standard Method on Page 24 B The Code Search Method is mainly used when enrolling a users Secondary Code and the User Slot Code is unknown The Code Search method only works if a users Primary Code is already enrolled but the Secondary Code is not See Enrolling Users with the Code Sear...

Страница 13: ...mming Mode Press to enter The Door LED will turn orange Enter the 3 digit User Slot number between 001 to 500 that you wish to enroll a Primary or Secondary code to For example the User Slot 003 represents User 3 a If the selected slot has no Primary Code the Mode LED will flash green indicating that the controller is ready to accept a Primary Code b If the selected slot already has a Primary Code...

Страница 14: ...of which user slots are empty and which user slots are not Deleting Primary and Secondary Codes using the Standard Method 1 2 8 Menu 8 3 4 Note Page 26 06 01 AC C31 Page 27 06 01 Deleting Primary and Secondary Codes using the Code Search Method 1 2 8 Menu 8 3 4 Note Enter Programming Mode Press to enter The Mode LED will turn red Enter the 3 digit User Slot 000 The Door LED will flash orange The c...

Страница 15: ...amming Code Replacing a lost Normal Secure Code 1 2 3 4 5 1 2 3 4 5 Remove power from the AC C31 Press the REX button Apply power to the unit with REX button pressed Release the REX button You now have 15 seconds to program a new Programming Code into the unit using the initial default code 1234 before the controller reverts to the existing code Remove power from the AC C31 Press the REX Button Ap...

Страница 16: ... Bypass Code Normal Secure Code Normal User Normally Closed Normally Open Open Code 1 Open Code 2 Primary Code Programming Code Programming Mode Proximity Cards Relay REX Request To Exit REX Secondary Code Secure Mode Secure User Strike Tamper Siren Tamper Siren Time Terminal Block The four digit code used to change the controllers Mode of Operation from Normal to Bypass Mode or vice versa The fou...

Страница 17: ... Rosslare Security Products S r l Via F lli Gabba 5 20121 Milano Italy Tel 39 0382 24800 Fax 39 0382 24800 E mail marco rogante tin it rosslarect aol com Rosslare NAPDC Suite 238 200 East Howard Street Des Plaines IL 60018 USA Tel 847 827 6330 Fax 847 827 6433 E mail support rosslare net International Web Site Asia Australia South America Europe Russia Middle East Africa United States and Canada A...

Отзывы: