![Rosslare AC-225-B Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/rosslare/ac-225-b-series/ac-225-b-series_hardware-installation_1489228025.webp)
Input and Output Connections
AC-225x-B Series Hardware Installation and User Manual
25
Double door controller:
(each door has two readers)
Door 1
–
OUT 1
Door 2
–
OUT 5
Four door controller:
(each door has one reader)
Door 1
–
OUT 1
Door 2
–
OUT 2
Door 3
–
OUT 5
Door 4
–
OUT 7
The output can sink current from any power supply (see Section 3.4).
4.4
Card Readers and Keypads
Each access control panel can be connected to a maximum of two readers or four
readers when using MD-D02B. There are three available types of reader:
▪
Card readers
▪
Keypads
▪
Dual keypad card readers
A keypad is required for any reader mode that requires PIN code entries, such as
"Card or PIN", "PIN Only" or "Card and PIN (Secured mode)".
When connecting a reader, the following should be defined:
Single door controller:
Door 1
–
Reader 1 IN/OUT
Door 1
–
Reader 2 OUT/ IN
Double door controller:
Door 1
–
Reader 1 IN/OUT
Door 2
–
Reader 2 IN/OUT
When using the MD-D02B, the following should be defined:
Double door controller:
(each door has two readers)
Reader 1
–
Door 1 IN/OUT
Reader 2
–
Door 1 OUT/IN
Reader 3
–
Door 2 IN/OUT
Reader 4
–
Door 2 OUT/IN
Four door controller:
(each door has one reader)
Reader 1
–
Door 1 IN/OUT
Reader 2
–
Door 2 IN/OUT
Reader 3
–
Door 3 IN/OUT
Reader 4
–
Door 4 IN/OUT
Use the AxTraxNG software to set the readers for IN or OUT use and to set the
data transmission format for each reader.
The reader’s tamper output connects to the access control panel's Reader
-Tamper
input. If the reader is interfered with, an alarm can be generated.
The panel's Reader G.LED output activates the reader’s green LED input when
operating in "Card and PIN" secure mode. While this mode is in force, users must
enter a PIN on the keypad immediately after entering the card.