Communications
AC-215x-B Series Hardware Installation Manual
35
The maximum distance from the Ethernet port of the panel to the LAN/WAN
connection is 100 m (330 ft).
When the TCP/IP connection is implemented over a WAN, it becomes possible
to connect through the Internet. This makes it possible to control multiple
access control panels worldwide, all from a single computer.
Before connecting a panel by TCP/IP connection for the first time, the
AxTraxNG software must configure the device. Settings then remain stored in
non-volatile memory on the device (see the AxTraxNG Software Manual).
When using an MD-N32, for a single panel, either an RS-232 cable or
Rosslare's MD-14U RS-485 to RS-232 converter can be used.
To connect an MD-N32 to more than one panel (up to 32 panels), Rosslare's
MD-14U RS-485 to RS-232 converter must be used. Connect the MD-14U
between the RS-485 access control panel network and the MD-N32 converter
Figure 21: Connecting Multiple Access Control Panels with MD-N32