![Rosslare AC-215 B Series Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/rosslare/ac-215-b-series/ac-215-b-series_installation-manual-and-users-manual_1489227022.webp)
Input and Output Connections
22
AC-215x-B Series Hardware Installation Manual
4.1.3
Normally Open Supervised Single Resistor Input Connection
Connect an 8.2 k
Ω
resistor in parallel to the input switch contacts.
Normally Open Supervised Input has 3 states:
Switch Open – Normal State:
Loop resistance = 8.2 k
Ω
Switch Closed – Abnormal State:
Loop resistance = 0 (short circuit).
Open circuit across input terminals – Trouble State:
Loop resistance = Infinite (open circuit).
Figure 11: Normally Open Supervised Input (Single Resistor) Connection
4.1.4
Normally Open Supervised Double Resistor Input Connection
Connect a 2.2 k
Ω
resistor in series to the input switch contacts.
Connect an 8.2
kΩ
resistor parallel to the input switch contacts.
Normally Open Supervised Input has 3 states:
Switch Open – Normal State:
Loop resistance = 10.4 k
Ω
Switch Closed – Abnormal State:
Loop resistance = 2.2 k
Ω
Open circuit (infinite loop resistance) or short circuit (0 resistance) across
input terminals – Trouble State.