4. Functioning and use

The remote programmable controller is the most suitable solution for this kind of applications: it 

is completely programmable,  both  on  regulation’s  side and user  interface’s  side,  and  it’s  very 
easy and intuitive.

The display  shows 4 red digits (incl. decimal digits) and 16 icons of different colours; keyboard 

has 4 buttons.

Fig.12 Control display

 

 UP/DOWN allows changing parameters and surfing into the menu; 

 SET/ENTER: pressing this button it is possible to enter the value change mode, to 

confirm the selected value or to go to the next level in the menu;

 STAND BY/ESC: Pressing this button for about 2 seconds, it is possible to switch the 

unit on or off. If pressed inside a menu, you will go up to the higher level.

Moreover following icons are used:

Icon summer 

: it’s on, when compressor is working, it flashes when compressor is in 

temporization before a starting.
Icon 1,2,3: identify the status of fan, indicating respectively the minimum, medium and 

maximum fan’s speed;

Icon of integrative resistance 

: identifies the status ON of the integrative electrical 

resistance: it flashes when the resistance is ON, otherwise it is off;

Icon alarm 

: identifies if there are alarms: it flashes when there is an alarm;

Icon defrost 

: identifies the status of defrosting: it is switched on when the solenoid is 

open;

Icon “set2” 

: it’s open when system’s set2 is setted.

To set the temperature press the button  “SET” for  at least  three seconds or  until the setted set 

point value is displayed and the led flashes.

NOTE:
In the first view the temperature in the upper part of the tank is displayed: this corresponds to the 
temperature of water ready for withdrawal.

 

 

 

 

 

Air Combo - installation, use and maintenance manual

AIRCOMBO_TEC_EN_4.07 

  

                                 

Page 20 of 28

                                       

Rossato Group Srl

Содержание Air Combo 200

Страница 1: ...Heat pump air water for domestic hot water Technical manual for installation use and maintenance AIR COMBO...

Страница 2: ...gy level Please always consult the instructions contained in the present manual when installing the unit The activities described in this manual need specialistic knowledge and professional experience...

Страница 3: ...drops of lower exchanger 10 2 5 Fan s characteristic curves 11 2 6 Dimensions and hydraulic connections 12 3 Installation 14 3 1 Safety recommendations 14 3 2 Place of installation and clearances 14...

Страница 4: ...o for different aims than specified Any other use is considered improper and not ammitted Rossato Group declines any responsibility in case of different uses than the ones the unit is planned and made...

Страница 5: ...laws of the country where the heat pump is installed CAUTION During unit s inactivity before commissioning it is appropriate to position the unit at repair from atmospheric agents For unloading opera...

Страница 6: ...cture made of steel sheets which are thermically insulated against condensation and covered with plastic material The heat pump is supported directly by the storage tank Air Combo installation use and...

Страница 7: ...he high efficient finned evaporator is made internally by copper pipes and externally by alluminium fins with hydrophilic treatment The quantity of fluid coming into the evaporator is regulated by a s...

Страница 8: ...d an electrical heater Control is electronic easy to set up and visualized through shining LEDs The display of thermoregulator shows water temperature state of compressor and fan and any alarm A tempe...

Страница 9: ...0 1300 Power W 25 67 Condenser Copper pipe Nominal air flow m3 h 350 Max available head Pa 30 Refrigerant R134a Charge g 370 Dimensions Dimensions Dimensions Dimensions Dimensions Air Combo 200 Air Co...

Страница 10: ...150 180 210 240 270 300 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 Perdite carico scambiatore inferiore Portata l h P mbar water flow l h Air Combo installation use and maintenance manual A...

Страница 11: ...curves NOTE the fourth speed level can be used only in exceptional cases and can be activated only by authorized personnel Air Combo installation use and maintenance manual AIRCOMBO_TEC_EN_4 07 Page 1...

Страница 12: ...imensioni Air Combo 200 Fig 5 LU RPER YLVWD GDOO DOWR Fig 3 865 765 680 345 245 165 169 280 750 855 1510 1570 640 160 160 289 259 Air Combo installation use and maintenance manual AIRCOMBO_TEC_EN_4 07...

Страница 13: ...r inlet 1 9 electric heater 1 1 4 5 circulation 1 2 10 e heater supply cable 8x40mm Sezione Air Combo 300 con attacchi Fig 6 Dimensioni Air Combo 300 Fig 7 1165 965 680 680 245 165 169 280 1020 1155 1...

Страница 14: ...Please ensure that the used rising means are safe and able to carry the load that has to be carried Do not stop or pass underneath the unit while rising or transporting it 3 2 Place of installation an...

Страница 15: ...y where the heat pump is installed DANGER During unpacking people incharged must wear proper equipment for individual safety such as safety gloves and glasses Demolition of packaging should be made as...

Страница 16: ...e tank s capacity It is recommended to install a manometer if it is not present anywhere else in the system The installer will take care to install an interception valve on hot water outlet in order t...

Страница 17: ...odel 200l is suitable for a surface of solar collectors of about 2 5 m2 usually one collector the model 300l is suitable for a surface of solar collectors of about 5 m2 usually two collectors Example...

Страница 18: ...ng canalizations it is possible to use a fourth speed level of the unit moving the black cable coming from the controller next to the brown cable of fan NOTE A complete electric schema is drawn in the...

Страница 19: ...rom gaskets or fittings Do not exceed the maximum available pressure indicated in the section general technical data Check all safety devices of hydraulic circuit Check the plug connected to supply so...

Страница 20: ...er it s on when compressor is working it flashes when compressor is in temporization before a starting Icon 1 2 3 identify the status of fan indicating respectively the minimum medium and maximum fan...

Страница 21: ...the system 4 2 1 Modify parameters by the user DANGER The final user is allowed to change only two parameters see following description Pressing the button for about 2 seconds following parameters wi...

Страница 22: ...ilegionella cycles 1 enables 0 disables 0 rtAL Period between 2 anti legionella cycles 7 days tAL Set point temperature to enable an antilegionella cycle 65 0 C SOLE Parameters of solenoid tISb Undern...

Страница 23: ...TC ambient air interrupted or in short circuit ALSD probe NTC display upper part of the tank interrupted or in short circuit C KO compressor broken V KO broken fan LP alarm of low evaporation temperat...

Страница 24: ...e Check for wear Technician Each six months Exchanger Check the control valve Technician Each six months Hydraulic circle Check safety devices Technician Each six months Hydraulic circle Check pressur...

Страница 25: ...from the valve 5 2 3 Supply cable Check the status of the supply cable in case of damage contact the installer to change it 5 2 4 Cap on compressor s service jack DANGER This operation must not be ma...

Страница 26: ...not start The unit has been just started up and the compressor delates to start Wait some minutes The compressor does not start Intervention of internal thermal protector Disconnect the unit wait unt...

Страница 27: ...Air Combo installation use and maintenance manual AIRCOMBO_TEC_EN_4 07 Page 27 of 28 Rossato Group Srl...

Страница 28: ...Rossato Group Srl Strada Portosello 77 b 04010 Borgo San Donato LT Tel 39 0773 844051 848778 info rossatogroup com www rossatogroup com...

Отзывы: