![Ross Ultricool Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/ross/ultricool/ultricool_user-manual_1488857017.webp)
Ultricool User Guide (v1.0)
Physical Installation • 17
To connect the power cables to the Ultricool
1. Connect the supplied power supply DC cable into the socket marked
PWR 1
on the Ultricool rear panel.
Figure 4.2 Ultricool — Power Connections
2. If available, connect the redundant power supply DC cable into the socket marked
PWR 2
.
3. Connect the supplied AC power cable into the power module(s).
4. Connect the supplied power cable’s three-prong male connector to Mains Power.
Using the ALARM Connector
for pin designations.
Figure 4.3 ALARM Connector — Pin Designations
for the pinout assignment of the ALARM port on the chassis.
Under normal operation (unit powered with no alarms activated), Pin
C
is connected to Pin
NO
. An alarm condition
connects Pin
C
to
Pin NC
)
Table 4.1 Alarm Pinouts
Pin Number
Function
NO
Normally Open
C
Common terminal
NC
Normally Closed
ENET
±15VDC
max.60W
NO
ALARM
C NC
PWR 2
PWR 1
5
6
7
8
1
2
3
4
To Power Source 1
To Power Source 2
NO
ALARM
C NC
Содержание Ultricool