background image

Important Regulatory and Safety Notices 

Before using this product and any associated equipment, refer to the “Important Safety Instructions” 
listed below so as to avoid personnel injury and to prevent product damage.  

 Products may require specific equipment, and /or installation procedures be carried out to satisfy 
certain regulatory compliance requirements. Notices have been included in this publication to call 
attention to these Specific requirements. 

Symbol Meanings 

 

 

This symbol on the equipment refers you to important operating and maintenance 
(servicing) instructions within the Product Manual Documentation. Failure to heed 
this information may present a major risk of damage or injury to persons or 
equipment. 

 

 

Warning

 

The symbol with the word 

“Warning”

 within the equipment manual indicates a 

potentially hazardous situation, which if not avoided, could result in death or serious 
injury. 

 

 

Caution

 

The symbol with the word “

Caution

” within the equipment manual indicates a 

potentially hazardous situation, which if not avoided, may result in minor or 
moderate injury. It may also be used to alert against unsafe practices. 

 

 

Notice

 

The symbol with the word “

Notice

” within the equipment manual indicates a 

situation, which if not avoided, may result in major or minor equipment damage or a 
situation which could place the equipment in a non-compliant operating state.  

 

ESD 

Susceptibility

 

This symbol is used to alert the user that an electrical or electronic device or 
assembly is susceptible to damage from an ESD event.  

Important Safety Instructions 

 

 

Caution

 

This product is intended to be a component product of the RossGear 8000 series 
frame. Refer to the RossGear 8000 series frame User Manual for important safety 
instructions regarding the proper installation and safe operation of the frame as well 
as it’s component products.  

 

 

Warning

 

Certain parts of this equipment namely the power supply area still present a safety 
hazard, with the power switch in the OFF position. To avoid electrical shock, 
disconnect all A/C power cords from the chassis' rear appliance connectors before 

ervicing this area. 

s

 

 

 

Warning

 

Service barriers within this product are intended to protect the operator and service 
personnel from hazardous voltages. For continued safety, replace all barriers after 
any servicing. 
This product contains safety critical parts, which if incorrectly replaced may present 
a risk of fire or electrical shock. Components contained within the product’s power 
supplies and power supply area, are not intended to be customer serviced and should 
be returned to the factory for repair. 
To reduce the risk of fire, replacement fuses must be the same type and rating. 
Only use attachments/accessories specified by the manufacturer. 

Содержание RSA-7806

Страница 1: ...ote Gain Stereo Amplifier User Manual Covers the following models RSA 7806 Remote Gain Stereo Amplifier RSA 7806 150 Remote Gain Stereo 150 Amplifier RSA 7806 600 Remote Gain Stereo 600 Amplifier Ross...

Страница 2: ...of copyrighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as a commitment by...

Страница 3: ...quipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or as...

Страница 4: ...th Canadian ICES 003 Cet appareil numerique de classe A est conforme la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of...

Страница 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Страница 6: ......

Страница 7: ...tallation 2 3 Remote Gain Control Connection 2 4 Cable Connections 2 5 ARP 7805 Installation 3 1 In This Chapter 3 1 Static Discharge 3 1 Unpacking 3 1 Overview 3 2 Installation 3 2 Cable Connections...

Страница 8: ...ii Contents RSA 7806 User Manual Iss 02...

Страница 9: ...n engineering and design expertise since 1974 You will be pleased at how easily your new RSA 7806 fits into your overall working environment Equally pleasing is the product quality reliability and fun...

Страница 10: ...r those who require 150 back termination RSA 7806 600 a 600 amplifier card for those who require 600 back termination The RSA 7806 card is housed in a RossGear AFR 7800 series audio frames See Chapter...

Страница 11: ...the Leitch ARG 880 5 year transferable warranty Documentation Terms The following terms are used throughout this guide RSA 7806 also refers to the RSA 7806 150 and the RSA 7806 600 unless otherwise n...

Страница 12: ...1 4 Introduction RSA 7806 User Manual Iss 02...

Страница 13: ...ESD Susceptibility Static discharge can cause serious damage to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wearing synthe...

Страница 14: ...805 provides controls for up to 12 channels from a distance of up to 400 meters Alternatively any 10K potentiometer may be used to provide remote control Installation of the RSA 7806 consists of setti...

Страница 15: ...ometer RV1 and RV4 will have no effect Board Installation Use the following steps to install the RSA 7806 cards in a RossGear audio distribution frame 1 Refer to the User Manual of the RossGear frame...

Страница 16: ...on of the RSA 7806 one or two potentiometers may be required per card Use the following steps and Figures 3 and 4 to connect the Remote Gain potentiometers 1 Connect the A Channel remote gain via the...

Страница 17: ...A Cabling Designations for RossGear 7814C and 7812C Series Frames Normal Mode 2 Channel Stereo Use the following table to connect the RSA 7806 to enable Normal Mode with 2 Channel Stereo Table 2 Norm...

Страница 18: ...udio Mixer Mode 2 Inputs 6 Outputs RSA 7806 Function Frame Marking RSA 7806 Function A IN A IN B IN B IN MIX OUT1 A OUT1 B OUT1 MIX OUT4 MIX OUT2 A OUT2 B OUT2 MIX OUT5 MIX OUT3 A OUT3 B OUT3 MIX OUT6...

Страница 19: ...figures and procedure below Figure 6 Connector Wiring for RSA 7806 Inputs and Outputs Use the following steps to wire the external cables to the removable terminal block connectors 1 Insert a wire in...

Страница 20: ...2 8 Installation and Setup RSA 7806 User Manual Iss 02...

Страница 21: ...to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wearing synthetic fiber clothing Always exercise proper grounding precautio...

Страница 22: ...nected according to the standard stereo wiring template outlined on the rear of the rack frame Installation Use the following steps to install the ARP 7805 Remote Audio Gain Panel 1 Install the RSA 78...

Страница 23: ...n provides instructions for connecting cables from the RSA 7806 to the ARP 7805 Connections are as follows Figure 7 Cabling Designations for RossGear RSA 7806 to the ARP 7805 RSA 7806 User Manual Iss...

Страница 24: ...3 4 ARP 7805 Installation RSA 7806 User Manual Iss 02...

Страница 25: ...Specifications In This Chapter This chapter contains the following sections RSA 7806 Technical Specifications RSA 7806 User Manual Iss 02 Specifications 4 1...

Страница 26: ...m Gain Range Normal Range 20dB Wide Range 30 65dB Frequency Response 0 025dB 20Hz to 10kHz Typically 0 08dB 20kHz THD N 0 02 18dBu 0 02 18dBm 0 02 18dBm Intermodulation 0 02 SMPTE Crosstalk Between Am...

Страница 27: ...le 2 Power Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power s...

Страница 28: ...rmation for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear RSA 7806 are to be conducted only by an authorized Ross Video Limit...

Страница 29: ...l additional User Manual AFR 7812C Audio Products Frame and Power Supply PS 7813 2 RU holds 12 modules includes 1 power supply AFR 7814C Audio Products Frame and Power Supply PS 7813 1 RU holds 4 modu...

Страница 30: ...Notes 6 2 Ordering Information RSA 7806 User Manual Iss 02...

Страница 31: ...Notes RSA 7806 User Manual Iss 02 Ordering Information 6 3...

Страница 32: ...fter hours Emergency 613 652 4886 ext 333 PHONE Fax 613 652 4425 General Information solutions rossvideo com E MAIL Technical Support techsupport rossvideo com Ross Video Limited 8 John Street Iroquoi...

Отзывы: