background image

 

 

EMC Notices 

US FCC Part 15 

This equipment has been tested and found to comply with the limits for a class A Digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which case  
users will be required to correct the interference at their own expense. 

 

 

 

Notice

 

Changes or modifications to this equipment not expressly approved by Ross Video 
Ltd. could void the user’s authority to operate this equipment. 

 CANADA 

This Class “A” digital apparatus complies with Canadian ICES-003.  

Cet appareil numerique de classe “A” est conforme à la norme NMB-003 du Canada. 

EUROPE 

This equipment is in compliance with the essential requirements and other relevant provisions of 

CE

 

Directive 93/68/EEC

INTERNATIONAL 

This equipment has been tested to 

CISPR 22:1997

 along with amendments 

A1:2000

 and 

A2:2002

 and 

found to comply with the limits for a Class A Digital device. 

 

 

 

Notice

 

This is a Class A product. In domestic environments this product may cause radio 
interference in which case the user may have to take adequate measures. 

 

Maintenance/User Serviceable Parts 

Routine maintenance to this RossGear product is not required. This product contains no user 
serviceable parts. If the module does not appear to be working properly, please contact Technical 
Support using the numbers listed under the “Contact Us” section on the last page of this manual.  All 
RossGear products are covered by a generous 5-year warranty and will be repaired without charge for 
materials or labor within this period.  See the “Warranty and Repair Policy” section in this manual for 
details.   

Содержание CMA-8011A

Страница 1: ...Ross Video Limited CMA 8011A Component Monitoring Amplifier User Manual Ross Part Number 8011ADR 004 Issue 05...

Страница 2: ...yrighted software is prohibited Notice The material in this manual is furnished for informational use only It is subject to change without notice and should not be construed as a commitment by Ross Vi...

Страница 3: ...quipment damage or a situation which could place the equipment in a non compliant operating state ESD Susceptibility This symbol is used to alert the user that an electrical or electronic device or as...

Страница 4: ...th Canadian ICES 003 Cet appareil numerique de classe A est conforme la norme NMB 003 du Canada EUROPE This equipment is in compliance with the essential requirements and other relevant provisions of...

Страница 5: ...ral resources Ross Video encourages you to use the appropriate take back systems These systems will reuse or recycle most of the materials from your end of life equipment in an environmentally friendl...

Страница 6: ......

Страница 7: ...ion Setting 2 3 Board Installation 2 3 BNC Labels 2 3 Cable Connections 2 4 LEDs 2 4 SMPTE 269M Fault Reporting 3 1 In This Chapter 3 1 Overview 3 1 Jumper Setup 3 2 Frame Connections 3 2 Details 3 2...

Страница 8: ...ii Contents CMA 8011A User Manual Iss 05...

Страница 9: ...Ross Video s experience in engineering and design expertise since 1974 You will be pleased at how easily your new CMA 8011A fits into your overall working environment Equally pleasing is the product q...

Страница 10: ...A 8011A also outputs four reclocked SDI streams The SDI input has an exceptionally good cable equalizer that will give error free performance with up to 305 meters 1000 ft of Belden 8281 cable Several...

Страница 11: ...ss Video 8000 series digital products frames and Leitch 6800 series frames 5 year transferable warranty Documentation Terms The following terms are used throughout this guide Frame refers to the DFR 8...

Страница 12: ...1 4 Introduction CMA 8011A User Manual Iss 05...

Страница 13: ...ESD Susceptibility Static discharge can cause serious damage to sensitive semiconductor devices Avoid handling circuit boards in high static environments such as carpeted areas and when wearing synth...

Страница 14: ...OMA OFF Used to output luminance only for the best picture on a monochrome monitor NORMAL Blanks all vertical interval information signals 20 line blanking 3 V BLANK SHORT Passes all vertical interval...

Страница 15: ...ignal and using a scope set the EQUALIZATION adjustment for correct chroma level at the destination Board Installation Use the following steps to install the CMA 8011A cards in a RossGear DFR 8104A or...

Страница 16: ...Composite Out 2 Composite Out 4 SDI Out 1 SDI Out 3 Composite Out 1 Composite Out 3 Figure 3 Cabling Designations for RossGear 8000 Series Frames It is not necessary to terminate unused analog or dig...

Страница 17: ...may still be restored correctly but the circuits will be working close to the limit of their capability and reliability cannot be assured Red This indicator identifies a problem either with the input...

Страница 18: ...2 6 Installation and Setup CMA 8011A User Manual Iss 05...

Страница 19: ...TE 269M fault reporting The card connects by means of an internal interface circuit to an auxiliary telco connector on RossGear 8000 series frames When the frame connection is interfaced with a custom...

Страница 20: ...PTE 269M Fault Reporting connection on RossGear 8000 series frames is provided by the auxiliary telco connector AUX A for interfacing with a customer designed alarm system AUX A Connector for SMPTE 26...

Страница 21: ...Specifications In This Chapter This chapter contains the CMA 8011A Technical Specifications table CMA 8011A User Manual Iss 05 Specifications 4 1...

Страница 22: ...20 80 850ps Typical Overshoot 8 SDI Output Delay SDI Input to SDI Output 13ns Number of Outputs 4 Standards NTSC or PAL composite video Output Impdeance 75 Output Return Loss 35dB to 6MHz Output Isol...

Страница 23: ...wer Check Check the power indicator LED on the distribution frame front panel for the presence of power If the power LED is not illuminated verify that the power cable is connected to a power source a...

Страница 24: ...oducts line provides all pertinent information for the safe installation and operation of your RossGear Product Ross Video policy dictates that all repairs to the RossGear CMA 8011A are to be conducte...

Страница 25: ...04A C Digital Products Frame with Cooling Fan Module and Power Supply PS 8102 1RU holds 4 modules includes 1 power supply DFR 8110A Digital Products Frame and Power Supply PS 8102 2RU holds 10 modules...

Страница 26: ...Notes 6 2 Ordering Information CMA 8011A User Manual Iss 01...

Страница 27: ...Notes CMA 8011A User Manual Iss 05 Ordering Information 6 3...

Страница 28: ...fter hours Emergency 613 652 4886 ext 333 PHONE Fax 613 652 4425 General Information solutions rossvideo com E MAIL Technical Support techsupport rossvideo com Ross Video Limited 8 John Street Iroquoi...

Отзывы: