SW1
- Output Setup
JP5
- Fault Report
JP1
- Output Mute
RV2
- EQ
Figure 2. User Control Locations
Analog Output Setup Switches
Use figure 2, the card labeling, and the following discussion to adjust the switch settings to configure
the analog output signal.
Table 1. Switch Settings
Position
Reference
SW1 Label
Description / Function
PAL
For 625 line systems
1 SYSTEM
NTSC
For 525 line systems
ON
The normal position
2 CHROMA
OFF
Used to output luminance only for the best picture on a
monochrome monitor.
NORMAL
Blanks all vertical interval information signals (20-line
blanking).
3 V
BLANK
SHORT
Passes all vertical interval signals occurring after the post-
equalizing pulses. If setup is ON, the signal will be non-
standard because set-up will be applied to the vertical interval.
ON
For NTSC - North America
4 SETUP
OFF
For all other systems
NORMAL
Normal operation
5 MODE
BARS
Produces an analog color bar output.
(Requires a valid 270Mb/s input signal.)
6 - 8
Reserved for future use.
2-2
•