5

SAFETY FEATURES

1. Safety limit switches and/or proximity sensors.

  For all machines equipped with raise/lower devices,

removable mix cans or other similar features, safety limit switches or proximity sensors are provided.  These
switches or sensors are required to be connected to the control systems in such a manner that will prevent
operation of the machine when the machine is in the raised (non-operational) position and/or the mix can is
removed and/or other safety features are not installed properly.

2. Guards and safety grating.

  All rotating parts or moving parts that may create the possibility of injury are

protected by guards and/or safety grating.  These guards or safety gratings are usually bolted in place to
allow access for periodic maintenance.  Guards and gratings may not always be installed with safety limit
switches or proximity sensors therefore, it is the responsibility of the owner and operator to ensure that these
devices are properly installed prior to operation.

3. Electrical Controls. 

All electrical control panels are built to meet the National Electrical Code at the time

of manufacture and are provided with disconnects that shut off power to the control circuits when the control
panel is open.  Fuses and thermal overloads are provided to protect the control circuits, motors and other
components from overloads.

4. Raise/Lower Controls.

  Many machines are equipped with air/oil hydraulic pistons or electronic/motorized

hydraulic lift systems which will raise/lower the mixer shafts, drive systems, mix cans or discharge platens into
and out of the mixing, discharge or operational position.  On machines where the operator may be allowed within
close proximity to the rotating shafts, discharge platens or pinch points, two (2) hand operator controls
(momentary spring return and/or push buttons) are provided to keep both of the operators hands away from the
dangerous areas during operation of the lift systems.

5. Emergency stop buttons.

  Emergency stop buttons (push/pull mushroom) are provided on all operator

control panels to allow for emergency shut down of the machinery.  These buttons will stop the machinery in
its current position although shafts and drives will drift/coast to a stop.

Содержание CDA-50

Страница 1: ...COMPANY 1 CHARLESROSS SONCOMPANY CHARLES ROSS SON COMPANY 710 OLD WILLETS PATH HAUPPAUGE NY 11788 PHONE 631 234 0500 FAX 631 234 0691 www mixers com CDA DUALSHAFTMIXER CDA 50 INSTALLATION MAINTENANCE...

Страница 2: ...DING CABLES 9 OPERATION 10 A HYDRAULIC LIFT 10 B MIX CAN 10 C VARIABLE SPEED CONTROL 10 D MIXING 10 E VACUUM MIXING 11 MAINTENANCE 12 A AGITATOR SHAFT SEALS VACUUM RATED MIXERS 12 B BEARINGS 13 C GEAR...

Страница 3: ...fety controls or other safety devices provided with the equipment must be in place and operational prior to operation of the equipment All rotating and or moving parts must be guarded during operation...

Страница 4: ...ve or the factory immediately E Mail Fax or Mail a copy of the inspection report and the delivery receipt indicating the problem areas at the time of delivery to sales mixers com Charles Ross Company...

Страница 5: ...Electrical Controls All electrical control panels are built to meet the National Electrical Code at the time of manufacture and are provided with disconnects that shut off power to the control circui...

Страница 6: ...d orreconditioningtherentedunit thecustomermust include the MSD sheet s of the material s that have been mixed in the rented unit The MSD sheet s are to be returnedwiththe rentedunit IftheMSDsheet s i...

Страница 7: ...e hydraulic lift cylinder in two directions at 90 degrees to each other front 0 degrees and side 90 degrees of the hydraulic lift cylinder This should provide a relatively vertically leveled installat...

Страница 8: ...ck the rotation of the shaft by jogging the drive motor Correct shaft rotation will be clock wise If the direction is reversed Lockout all power to the controls and reverse the connection of any two o...

Страница 9: ...ith oil NEVERALLOWTHESE SEALSAND BEARINGSTO RUN DRY Check the oil level at the oil gauge sight on the side of the bearing housing tower and add oilasnecessarytokeepthissight gaugefullatthecenterline U...

Страница 10: ...e Hydraulic Cylinder or on Base Extensions which are at the floor level Appropriate grounding cables should also be attached to the Mix Can C VARIABLE SPEED CONTROL 1 The speed of the agitators can be...

Страница 11: ...ncrease the evaporation of other volatiles such as solvents or wetting agents The reaction of each formula to vacuum is different and should be closely monitored during trial runs The horse power requ...

Страница 12: ...the shaft surface to its original 240 grit finish This is done by using 240 grit sand paper and then finish using a White Scotch Brite Hand Pad 7445 The shaft surface should appear as new with all scr...

Страница 13: ...Dry Running Flexi Lip Sealsand an ATMOSPHERIC RATED MIXER withoutseals are lubricated by grease and should be greased regularly or at least every 500 hours If a bearing makes anunusual noise orruns un...

Страница 14: ...per needs to be replaced 1 Pulloutthe oldwiperand thoroughly clean thegroove 2 Gentlytap the new wiperintothe groove witha fiber hammer alap jointwillresult 3 Pull out both ends of the joint fit the e...

Страница 15: ...snotimportant Also refertotheVendorLiteratureformorespecific information 1 Reducer SyntheticAGMAlubricant 7EPor 8EP ISO ASTM viscosity grade 460 680 2 Bearings Anyhightemperature solvent resistant syn...

Страница 16: ...NNET CDA 50 1 11 4A0186 SIGHT GLASS LIQUID LEVEL BRASS 500 NTPF 100PSI 1 12 7F0052 FITTING GREASE 1 8 NPTM 1 13 5A0048 MOTOR 5HP 1800RPM 3 60 230 460V 2 WING ANCHOR 1 14 4L0041 SHEAVE TAPER LOCK DISPE...

Страница 17: ...RC3177 SHAFT DISPERSER CDA 50 1 44 4B0020 BEARING UPPER BALL SEALED TYPE DISPERSER 1 45 4B0007 BEARING LOWER DISPERSER 1 46 7J0019 RING RETAINING INTERNAL 1 47 7K0011 WASHER LOCK BEARING 1 48 7K0005...

Страница 18: ...DA 50 1 67 RA2173 BUTTON SHAFT ANCHOR SS CDA 50 2 68 SCRAPER SIDE UPPER MID TEFLON OPTION 1 69 SCRAPER SIDE LOWER TEFLON OPTION 1 70 SCRAPER BOTTOM INNER TEFLON OPTION 1 71 SCRAPER BOTTOM OUTER TEFLON...

Страница 19: ...2017 CHARLES ROSS SON COMPANY 19 SIDE VIEW CDA 50...

Страница 20: ...2017 CHARLES ROSS SON COMPANY 20 DRIVE VIEW CDA 50...

Страница 21: ...2017 CHARLES ROSS SON COMPANY 21 VACUUM COVER VIEW CDA 50...

Страница 22: ...2017 CHARLES ROSS SON COMPANY 22 ANCHOR SHAFT BEARING HOUSING VIEW CDA 50...

Страница 23: ...2017 CHARLES ROSS SON COMPANY 23 ANCHOR BLADE W SCRAPERS VIEW CDA 50...

Страница 24: ...2017 CHARLES ROSS SON COMPANY 24 DISPERSER SHAFT BEARING HOUSING VIEW CDA 50...

Страница 25: ...2017 CHARLES ROSS SON COMPANY 25 MIX CAN VIEW...

Страница 26: ...2017 CHARLES ROSS SON COMPANY 26 APPENDIX VENDOR PRODUCT INFORMATION...

Отзывы: